DCR-IP45, DCR-IP45E, DCR-IP55, DCR-IP55E (serv.man2) - Sony Movie Service Manual (repair manual). Page 122

Read Sony DCR-IP45 / DCR-IP45E / DCR-IP55 / DCR-IP55E (serv.man2) Service Manual online

5-56
DCR-IP45/IP45E/IP55/IP55E
7-2.
AGC Adjustment (VC-291 Board)
Adjust the AGC of IC1301.
Mode
Playback
Signal
Recorded signal at “Preparations
Before Adjustments”
Measurement Point
Data of page: 3, address: 01
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
6B
Specified Value
00
Note1: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations Before Adjustments”
2
0
01
01
Set the data.
3
9
9A
64
Set the data, and press PAUSE
button.
4
9
9C
11
Set the data, and press PAUSE
button.
5
3
00
09
Set the data, and press PAUSE
button.
6
3
01
Check that the data changes
from “09” to “00”.
If the data doesn’t change to
“00”, there are errors. (Note2)
7
9
9C
10
Set the data, and press PAUSE
button.
8
9
9A
16
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2: If the data doesn’t changes to “00”, adjustment has errors. Contents
of the error is written into page: 3, addresses: 02. See the following
table.
Data of page: 3,
address: 02
01
02
03
04
Contents of error
Gain was smaller than a specified value.
Gain was larger than a specified value.
Gain exceeded a specified range.
Gain exceeded a specified range.
7-3.
Pch AEQ & LMS Adjustment (VC-291 Board)
Adjust the equalizer to minimize the Pch error rate.
Mode
Playback
Signal
Recorded signal at “Preparations
Before Adjustments”
Measurement Point
Data of page: 3, address: 01
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
3D to 51, 67, 69
Specified Value
00
Note1: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations Before Adjustments”
2
0
01
01
Set the data.
3
9
9A
64
Set the data, and press PAUSE
button.
4
9
9C
11
Set the data, and press PAUSE
button.
Pch AEQ adjustment
5
3
00
0A
Set the data, and press PAUSE
button.
6
3
01
Check that the data changes to “00”.
If the data doesn’t change to
“00”, there are errors. (Note2)
Pch LMS adjustment
7
3
00
10
Set the data, and press PAUSE
button.
8
3
01
Check that the data changes to “00”.
If the data doesn’t change to
“00”, there are errors. (Note3)
9
9
9C
10
Set the data, and press PAUSE
button.
10
9
9A
16
Set the data, and press PAUSE
button.
11
0
01
00
Set the data.
Note2: If the data doesn’t changes to “00”, AEQ adjustment has errors.
Contents of the error is written into page: 3, addresses: 06. See the
following table.
Note3: If the data doesn’t changes to “00”, LMS adjustment has errors.
Contents of the error is written into page: 3, addresses: 02. See the
following table.
Data of page: 3,
address: 06
01
02
03
Contents of error
Pch adjustment has errors.
Mch adjustment has errors.
Adjustment was interrupted. (Eject etc.)
Data of page: 3,
address: 02
01
02
Contents of error
LMS adjustment time out
Envelope is abnormal
Page of 127