Read Sony DCR-IP210 / DCR-IP210E / DCR-IP220 / DCR-IP220E (serv.man4) Service Manual online
6-6
DCR-IP210/IP210E/IP220/IP220E
1-1-2.
Preparations
Note1:
For details of how remove the cabinet and boards, refer to “2.
DISASSEMBLY”.
DISASSEMBLY”.
Note2:
When performing only the adjustments, the lens block and boards
need not be disassembled.
need not be disassembled.
Note3:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
address: 10 is “00”. If not, set data: 00 to this address.
1)
Connect the equipment for adjustments according to Fig. 6-1-3.
Note4:
Be careful not to touch the ST-076 board (Flash drive circuit).
Because there is a danger of electric shock when the ST-076 board
is handled by hand.
Because there is a danger of electric shock when the ST-076 board
is handled by hand.
Note5:
Perform “Zoom Key Center adjustment” and “Flange back
Adjustment” under the condition that the zoom switch (RV4001
of the control switch block (SS-2980)) is surely connected.
Adjustment” under the condition that the zoom switch (RV4001
of the control switch block (SS-2980)) is surely connected.
Note6:
As removing the control switch block (PW-2980)) means removing
the lithium 3V power supply (BT4101 on the control switch block
(PW-2980)), data such as date, time, user-set menus will be lost.
After completing adjustments, reset these data.
But the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the lithium 3V power
supply is removed. (Refer to “6-4. Service Mode” for the self-
diagnosis data and the data on history of use.)
the lithium 3V power supply (BT4101 on the control switch block
(PW-2980)), data such as date, time, user-set menus will be lost.
After completing adjustments, reset these data.
But the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the lithium 3V power
supply is removed. (Refer to “6-4. Service Mode” for the self-
diagnosis data and the data on history of use.)
Note7:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (PW-2980) removed. After
completing adjustments, be sure to exit the “Forced Camera
Power ON Mode”.
The above procedure will enable the camera power to be turned
on with the control switch block (PW-2980) removed. After
completing adjustments, be sure to exit the “Forced Camera
Power ON Mode”.
Note 8:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
1.5 m
Front of the lens
Pattern box
Fig. 6-1-2.
Click on the first or last page to see other DCR-IP210 / DCR-IP210E / DCR-IP220 / DCR-IP220E (serv.man4) service manuals if exist.