6-16
DCR-HC94E/HC96/HC96E_ADJ
1-2-3.
Initialization of E, F, 14, 19, 1E, 1F Page Data
1.
Initializing of E, F, 14, 19, 1E, 1F Page Data
Note 1: If “Initialization of Pages E, F, 14, 19, 1E, 1F” is ex-
ecuted, all data on pages E, F, 14, 19, 1E, 1F are initial-
ized. (Only an individual page cannot be initialized)
Note 2: If the E, F, 14, 19, 1E, 1F page data has been initialized,
the following adjustments need to be performed again.
1) Modification of E, F, 14, 19, 1E, 1F page data
2) Camera system adjustment (if all areas were initial-
ized)
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
14
Adjustment Address
00 to FF
Adjustment Page
19
Adjustment Address
00 to FF
Adjustment Page
1E
Adjustment Address
00 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE button.
3
6
01
2D: NTSC model
2F: PAL model
4
6
03
03
Press PAUSE (Write) button.
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE (Write) button.
7
Perform “Modification of E,
F, 14, 19, 1E, 1F Page Data”
Note 3: NTSC model: DCR-HC96
PAL model: DCR-HC94E/HC96E
2.
Modification of E, F, 14, 19, 1E, 1F Page Data
If the E, F, 14, 19, 1E, 1F page data has been initialized, change
the data of the “Fixed data-2” address shown in the following table
by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 14, 19, 1E, 1F, set data: 01 to
page: 0, address: 10, and then select pages 4, 9, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification E, F, 14, 19, 1E,
1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
Page of 79
Display

Click on the first or last page to see other DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) service manuals if exist.