DCR-HC85, DCR-HC85E (serv.man4) - Sony Movie Service Manual (repair manual). Page 28

Read Sony DCR-HC85 / DCR-HC85E (serv.man4) Service Manual online

6-25
DCR-HC85/HC85E
3. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified Value1
40 to C0
Specified Value2
03 to 70
Specified Value3
90 to FD
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
Perform this adjustment before “Flange Back Adjustment”.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
5A
Check that the data satisfies the
specified value 1.
5
F
5B
Check that the data satisfies the
specified value 1.
6
F
5C
Check that the data satisfies the
specified value 1.
7
F
5D
Check that the data satisfies the
specified value 1.
8
F
5E
Check that the data satisfies the
specified value 2.
9
F
5F
Check that the data satisfies the
specified value 3.
10
F
60
Check that the data satisfies the
specified value 2.
11
F
61
Check that the data satisfies the
specified value 3.
12
F
62
Check that the data satisfies the
specified value 2.
13
F
63
Check that the data satisfies the
specified value 3.
14
F
64
Check that the data satisfies the
specified value 2.
15
F
65
Check that the data satisfies the
specified value 3.
Note5:
The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
Page of 69
Display

Click on the first or last page to see other DCR-HC85 / DCR-HC85E (serv.man4) service manuals if exist.