DCR-HC62, DCR-HC62E (serv.man4) - Sony Movie Service Manual (repair manual). Page 17

Read Sony DCR-HC62 / DCR-HC62E (serv.man4) Service Manual online

6-16
DCR-HC62/HC62E_ADJ
1-2-3.
Initialization of 63 to 6F Page Data
1.
Initializing of 63 to 6F Page Data
Note 1: If “Initialization of Pages 63 to 6F” is executed, all data
on pages 63 to 6F are initialized. (Only an individual
page cannot be initialized)
Note 2: If the 63 to 6F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of 63 to 6F page data
2) Camera system adjustment
Adjustment Page
63
Adjustment Address
00 to 4F
Adjustment Page
64
Adjustment Address
00 to 8F
Adjustment Page
65
Adjustment Address
00 to 2F
Adjustment Page
66
Adjustment Address
00 to FF
Adjustment Page
67
Adjustment Address
00 to 6F
Adjustment Page
68
Adjustment Address
00 to AF
Adjustment Page
69
Adjustment Address
00 to 4F
Adjustment Page
6A
Adjustment Address
00 to AF
Adjustment Page
6B
Adjustment Address
00 to 5F
Adjustment Page
6C
Adjustment Address
00 to 4F
Adjustment Page
6D
Adjustment Address
00 to FF
Adjustment Page
6E
Adjustment Address
00 to 1F
Adjustment Page
6F
Adjustment Address
10 to FF
Initializing method:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
3
6
01
Set the following data, and
press PAUSE (Write) button.
2D: NTSC model
2F:
PAL model
4
6
03
FF
Press PAUSE (Write) button.
5
6
03
01
Press PAUSE (Write) button.
6
6
02
Check the data changes to
“01”.
7
6
01
00
Press PAUSE (Write) button.
8
Perform “Modification of 63
to 6F Page Data”
Note 3: NTSC model: DCR-HC62
PAL model: DCR-HC62E
2.
Modification of 63 to 6F Page Data
If the 63 to 6F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 63 to 6F, set data: 06 to page:
0, address: 10, and then select pages 3 to F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) Check that the data at the addresses for adjustment are initial
values (adjustment initial values) listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 63 to 6F page
data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
3.
63 Page table
Note 1: If reading/writing data on pages 63, set data: 06 to page:
0, address: 10, and then select pages: 3. By this data
setting, the pages 63 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 09
Fixed data-1 (Initialized data)
0A
0B
Fixed data-2
0C to 4F
Fixed data-1 (Initialized data)
Page of 74
Display

Click on the first or last page to see other DCR-HC62 / DCR-HC62E (serv.man4) service manuals if exist.