DCR-HC51E, DCR-HC52, DCR-HC52E, DCR-HC53E, DCR-HC54, DCR-HC54E (serv.man4) - Sony Movie Service Manual (repair manual). Page 15

Read Sony DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) Service Manual online

6-14
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
1-2-3.
Initialization of E, F, 1F Page Data
Note: Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of E, F, 1F Page Data
Note 1: If “Initialization of Pages E, F, 1F” is executed, all data
on pages E, F, 1F are initialized. (Only an individual page
cannot be initialized)
Note 2: If the E, F, 1F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of E, F, 1F page data
2) Camera system adjustments
Note 3: NTSC model: DCR-HC52/HC54
PAL model: DCR-HC51E/HC52E/HC53E/HC54E
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
6
01
Set the following data, and
press PAUSE (Write) button.
2D: NTSC model
2F: PAL model
4
6
03
FF
Press PAUSE (Write) button.
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE (Write) button.
7
Perform “Modification of E,
F, 1F Page Data”
2.
Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 1F, set data: 01 to page: 0,
address: 10, and then select pages F. After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification E, F, 1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
4
Perform “36MHz Origin
Oscillation Adjustment” of
1-3. CAMERA SYSTEM
ADJUSTMENTS.
Page of 62
Display

Click on the first or last page to see other DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) service manuals if exist.