DCR-HC47E, DCR-HC48, DCR-HC48E (serv.man4) - Sony Movie Service Manual (repair manual). Page 49

Read Sony DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) Service Manual online

6-47
DCR-HC47E/HC48/HC48E_ADJ
D
1
 (decimal)
D
2
 (decimal)
H
1
 (hexadecimal)
(Service model code)
00001 to 65535
D
1
FE
65536 to 131071
D
1
 
– 65536
FE
131072 to196607
D
1
 
– 131072
FE
196608 to 262143
D
1
 
– 196608
FE
262144 to 327679
D
1
 
– 262144
FE
327680 to 393215
D
1
 
– 327680
FE
393216 to 458751
D
1
 
– 393216
FE
458752 to 524287
D
1
 
– 458752
FE
524288 to 589823
D
1
 
– 524288
FE
589824 to 655359
D
1
 
– 589824
FE
655360 to 720895
D
1
 
– 655360
FE
720896 to 786431
D
1
 
– 720896
FE
786432 to 851967
D
1
 
– 786432
FE
851968 to 917503
D
1
 
– 851968
FE
917504 to 983039
D
1
 
– 917504
FE
983040 to 999999
D
1
 
– 983040
FE
Table 6-3-2
4) Enter H
1
 to address: E5 on page: C.
Example: If H
1
 = FE,
select page: C, address: E5, and set data: FE, then press the
PAUSE (Write) button.
5) From Table 6-3-3, obtain the maximum decimal number less
than D
2
, and it is assumed to be D
3
.
Example: If D
2
 = 12345.
D
3
 = 12288
6) From Table 6-3-3, obtain a hexadecimal number that corre-
sponds to D
3
, and it is assumed to be H
3
.
Example: If D
3
 = 12288,
H
3
 = 3000
7) Caluculate D
4
  using following equations (decimal
caluculation). (0   D
4
 
 225)
D
4
 = D
2
 – D
3
Example: If D
2
 = 12345 and D
3
 = 12288,
D
4
 = 12345 – 12288 = 57
8) Convert D
4
 into a hexadecimal number to obtain H
4
. (See Table
6-4-1 “Hexadecimal - decimal conversion table” in 6-4. Ser-
vice Mode)
Example: If D
4
 = 57,
H
4
 = 39
9) Enter higher two digits of H
3
 to address: E6 on page: C.
Example: If H
3
 = 3000,
select page: C, address: E6, and set data: 30, then press the
PAUSE (Write) button.
10) Enter H
4
 to address: E7 on page: C.
Example: If H
4
 = 39,
select page: C, address: E7, and set data: 39, then press the
PAUSE (Write) button.
11) Select page: 0, address: 01, and set data: 00.
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENTS
1.
Initialization of EEPROM Data
If the  EEPROM data is erased due to some reason, perform “1-2.
INITIALIZATION OF  EVR DATA ”, of “6-1. CAMERA SEC-
TION ADJUSTMENT”
2.
Node Unique ID No. Input
Note 1: Perform “2-2. Input of Serial No.” if the data on page C
has been cleared and Original node unique ID No. is un-
certain.
Usually, read the data on page C before repair, and write
it after repair.
Note 2: Check that the data of page: 0, address: 10 is “00”.
2-1. Input of Company ID
Write the company ID to the EEPROM (nonvolatile memory).
Page
C
Address
E0, E1, E2, E3, E4
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: C, and enter the following data.
Note 3: Each time the data is set, press the PAUSE (Write) but-
ton on the adjusting remote commander.
Address
Data
E0
08
E1
00
E2
46
E3
01
E4
02
3) Select page: 0, address: 01, and set data: 00.
2-2. Input of Serial No.
Write the serial No. and model code to the EEPROM (nonvolatile
memory).
In writing the serial No., a decimal number should be converted
into a hexadecimal number.
Page
C
Address
E5, E6, E7
1) Select page: 0, address: 01, and set data: 01.
2) Read the serial No. from the model name label, and it is as-
sumed to be D
1
.
Example: If serial No. is “77881”,
D
1
 = 77881
3) From Table 6-3-2, obtain D
2
 and H
1
 that correspond to D
1
.
Example: If D
1
 = 77881,
D
2
 = D
1
 – 65536 = 12345
H
1
 = FE
Page of 77
Display

Click on the first or last page to see other DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) service manuals if exist.