DCR-HC47E, DCR-HC48, DCR-HC48E (serv.man4) - Sony Movie Service Manual (repair manual). Page 48

Read Sony DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) Service Manual online

6-46
DCR-HC47E/HC48/HC48E_ADJ
3-1-4.
Alignment Tapes
Use the alignment tapes shown in the following table.
Use tapes specified in the signal column of each adjustment.
Name
Use
Tracking standard (XH2-1)
Tape path adjustment
SW/OL standard (XH2-3)
Switching position adjust-
ment
Audio operation check
Audio system adjustment
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
Operation check
(XH5-5 (NTSC), XH5-5P (PAL))
Fig. 6-3-2 shows the 75% color bar signals recorded on the align-
ment tape for Audio Operation Check.
Note: Measure with video terminal (Terminated at 75 
Ω)
Fig. 6-3-2. Color bar signal of alignment tapes
For NTSC model
For PAL model
Color bar signal waveform
Color bar pattern
Color bar signal waveform
1 V
0.714 V
0.286 V
White (75%)
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
0.286 V
Q
I
Horizontal sync signal
(75%)
White
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Q
I
White
(100%)
Black
1 V
0.7 V
0.3 V
White (100%)
Ye
llo
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
Horizontal sync signal
0.3 V
(100%)
Ye
llo
w
Cy
an
Green
Magenta
Red
Blue
White
Blac
k
Color bar pattern
3-1-5.
Output Level and Impedance
Video output
A/V OUT jack
Video signal: 1 Vp-p, 75 
Ω unbalanced,
sync negative
S video output
A/V OUT jack
Luminance signal: 1 Vp-p, 75 
Ω unbalanced,
sync negative
Chrominance signal: 0.286 Vp-p, 75 
Ω unbalanced (NTSC)
: 0.300 Vp-p, 75 
Ω unbalanced (PAL)
Audio output
A/V OUT jack
Input impedance: More than 47 k
Output level: 327 mV (at load impedance 47 k
Ω)
Output impedance: Below 2.2 k
Page of 77