6-72
DCR-HC17E/HC19E/HC21/HC21E/HC22E/HC32/HC32E/HC33/HC33E
3.
Emergence Memory Address (MS model)
3-1.
Emergency Memory Address (Camera section)
Page 1F
Address 1C to 1F
Note:
If reading/writing data on pages 1F, set data: 01 to page: 0,
address: 10, and then select pages: F. By this data setting,
the pages 1F can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
Address
Contents
1C
EMG code when first error occurs
1D
EMG code when second error occurs
1E
EMG code when third error occurs
1F
EMG code when last error occurs
When no error occurs in this unit, data “00” is written in the above
addresses (1C to 1F). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (1C). In the same way, when the second error occurs, the
data corresponding to the error is written in the second emergency
address (1D).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (1F).
Note:
After completing adjustments, be sure to initialize the data
of addresses 1C to 1F to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
FD
Press PAUSE button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE button.
5
0
01
00
3-2.
EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in 1F
page, addresses 1C to 1F. The type of error indicated by the code
are shown in the following table.
Code
Emergency Type
00
No error
4.
Emergence Memory Address (Mechanism
section)
Page C
Address F4 to FF
Address
Contents
F4
EMG code when first error occurs
F6
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
F7
Lower: MSW code to be moved when first error
occurs
F8
EMG code when second error occurs
FA
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
FB
Lower: MSW code to be moved when second error
occurs
FC
EMG code when last error occurs
FE
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
FF
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note:
After completing adjustments, be sure to initialize the data
of addresses F4 to FF to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
37
Press PAUSE button.
3
3
02
Check the data changes to
“00”.
4
0
01
00
Page of 88