DCR-DVD510E, DCR-DVD910, DCR-DVD910E, HDR-UX10, HDR-UX10E, HDR-UX19E, HDR-UX20, HDR-UX20E, HDR-UX9E (serv.man2) - Sony Movie Service Manual (repair manual). Page 13

Read Sony DCR-DVD510E / DCR-DVD910 / DCR-DVD910E / HDR-UX10 / HDR-UX10E / HDR-UX19E / HDR-UX20 / HDR-UX20E / HDR-UX9E (serv.man2) Service Manual online

1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DCR-DVD510E/DVD910/DVD910E/
HDR-UX9E/UX10/UX10E/UX19E/UX20/UX20E_L2
1-5. METHOD OF COPING WITH SHIFT LENS ERROR
about 330 msec
Fig. 1
Measurement points on the LD-233 board
IC5501
LD-233 BOARD
R5526
R5534
R5549
R5549: No Mount
(Short Land)
Fig. 2
Change in output voltage of R5549 on the LD-233 board
Note: The length of low section will vary a little depending on the
conditions.
1-5-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5549 in the periphery of IC5501 on the LD-233 board, turn the
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
the camera control circuit (IC1301 of VC-521 board) periphery.
Note:
When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
IC1301
VC-521 BOARD (SIDE A)
Fig. 3
Measurement points on the VC-521 board
Ver. 1.1  2008.02
Page of 103
Display