CCD-TRV54E, CCD-TRV56E, CCD-TRV62, CCD-TRV64E, CCD-TRV72, CCD-TRV82, CCD-TRV94, CCD-TRV94E - Sony Movie Service Manual (repair manual). Page 114

Read Sony CCD-TRV54E / CCD-TRV56E / CCD-TRV62 / CCD-TRV64E / CCD-TRV72 / CCD-TRV82 / CCD-TRV94 / CCD-TRV94E Service Manual online

5-3
Note 3: Setting the “forced camera power supply ON mode”
1) Set data: 01 to page: 0, address: 01.
2) Set data: 21 to page: D, address: 10, and press
t he  P A US E   but t on  of   t he  ad jus t i ng r e m ot e
commander.
The camera power supply can be turned ON even if the cabinet
(R) has been removed using the above steps. After completing
adjustments, be sure to exit the “forced Camera power supply
ON mode”.
Note 4: Exiting the “forced camera power supply ON mode”
1) Set data: 01 to page: 0, address: 01.
2) Set data: 00 to page: D, address: 10, and press
t he  P A US E   but t on  of   t he  ad jus t i ng r e m ot e
commander.
3) Set data: 00 to page: 0, address: 01.
1-1-2. Preparations
Note 1: Refer to “Section 2 DISASSEMBLY” for details of
how to remove the cabinet and boards.
Note 2: If performing only adjustments, the lens block and
VC-190 board need not be adjusted.
1)
Connect the adjusting equipment according to Fig. 5-1-3,
4.
2)
The front panel block (MI-27/MI-28/MA-298 boards) need
not be connected.
To remove, disconnect the following connector.
1.
CN303 (26P, 0.5 mm) of MI-27/28 board (3.5"
LCD/4" LCD model)
CN303 (14P, 0.5 mm) of MA-298 board (2.5"
LCD model)
(Refer to pages 5-58 for the Arrangement Diagram for
Adjustment Parts.)
3)
The accessory shoe need not be connected.
To remove, disconnect the following connector.
1.
CN205 of VC-190 board (10P, 0.5 mm)
(Refer to pages 5-92 for the Arrangement Diagram for
Adjustment Parts.)
4)
The viewfinders (VF-111, 112 boards (COLOR EVF
model), VF-99/102 board (B/W EVF model) need not be
c o n ne ct ed . T o  re mo ve ,  di sco nne c t  t he  fol lo wi ng
connector.
1.
CN111 of VC-190 board (20P, 0.5 mm)
(Refer to pages 5-58 for the Arrangement Diagram for
Adjustment Parts.)
5)
By setting the “forced power supply ON mode”, the
camera power supply can be turned ON even if the cabinet
(R) (power switch, speaker, SD-27/28 board) has been
removed. When removing the cabinet (R), disconnect the
following two connectors. However, as removing CN1953
means removing the lithium 3V power supply, data such
a s d a te,  t i me , us e r-set  m e nus  wil l  be  l ost . Aft er
a d ju s tme nt s , re s e t t he se  da ta . If CN1 95 3 has b een
removed, the self-diagnosis data, data on history of use
(total drum rotation time, date of when the user first
turned the power ON, and the date of when condensation
occurred the last time) will be lost. Before removing, note
d o wn   th e  s e l f-d i a gn osi s d at a  a nd  d at a o f page: 3,
a d d re ss :E 0  t o   E9 . (Re fe r  to  th e “ Se rvi c e Mod e” o f
“VIDEO SECTION ADJUSTMENTS” for the data on the
history of use.)
1.
CN1950 of VC-190 board (28P, 0.5 mm)
2.
CN1953 of VC-190 board (28P, 0.5 mm)
(Refer to pages 5-58 for the Arrangement Diagram for
Adjustment Parts.)
After the adjustments, be sure to exit the “forced camera
power supply ON mode”.
Fig. 5-1-2.
Pattern box
1.5m
Front of lens
Page of 127
Display

Click on the first or last page to see other CCD-TRV54E / CCD-TRV56E / CCD-TRV62 / CCD-TRV64E / CCD-TRV72 / CCD-TRV82 / CCD-TRV94 / CCD-TRV94E service manuals if exist.