CCD-TRV107, CCD-TRV108, CCD-TRV308, CCD-TRV408, CCD-TRV608 (serv.man3) - Sony Movie Service Manual (repair manual). Page 9

Read Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 (serv.man3) Service Manual online

— 9 —
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
 : 
Changed portion.
Page
CORRECT
5-24
1-5.
LCD SYSTEM ADJUSTMENT
Note 4:
Connect the adjustment remote commander to CN713 of VC-272
board via I/F unit for LANC control (J-6082-521-A) and CPC jig
connector (J-6082-539-A). To operate the adjustment remote
commander, connect the AC power adapter (8.4Vdc) to the DC
IN jack of I/F unit for LANC control, or connect the L series Info-
LITHIUM battery to the battery terminal of I/F unit for LANC
control.
 : 
Changed portion.
Page
CORRECT
5-28
5-2. MECHANISM SECTION ADJUSTMENT
2-1. ADJUSTMENT REMOTE COMMANDER
Connect the adjustment remote commander to CN713 of VC-272
board via I/F unit for LANC control (J-6082-521-A) and CPC jig
connector (J-6082-539-A). To operate the adjustment remote
commander, connect the AC power adapter (8.4Vdc) to the DC IN
jack of I/F unit for LANC control, or connect the L series Info-
LITHIUM battery to the battery terminal of I/F unit for LANC
control.
2-3. TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
6)
Connect the oscilloscope to I/F unit for LANC control.
Channel 1: PB RF (Pin 9 of CN713)
External trigger: SWP (Pin 5 of CN713)
 : 
Changed portion.    
 : 
Added portion.
Page
CORRECT
5-29
5-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
3-1-1. Equipment to Required
13) Adjustment remote commander (J-6082-053-B)
14) CPC jig connector (J-6082-539-A)
15) I/F unit for LANC control (J-6082-521-A)
5-30
3-1-2.
Precautions on Adjusting
1)
Connect the adjustment remote commander to CN713 of VC-
272 board via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A). To operate the adjustment
remote commander, connect the AC power adapter to the DC
IN jack of I/F unit for LANC control, or connect the L series
Info-LITHIUM battery to the battery terminal of I/F unit for
LANC control.
Page of 10
Display

Click on the first or last page to see other CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 (serv.man3) service manuals if exist.