CCD-TR913E, CCD-TR950E - Sony Movie Service Manual (repair manual). Page 122

Read Sony CCD-TR913E / CCD-TR950E Service Manual online

5-42
(75
)
600
Video
L
R
Audio
AUDIO OUT
L
47k
47k
 (1-249-437-11)
600
 
(270
 (1-249-410-11) + 330
 
(1-249-411-11))
Pattern generator
Audio oscillator
Main unit
Attenuator
Audio level meter
VIDEO OUT
R
IR receiver jig
Fig. 5-3-18.
3. IR Audio Deviation Adjustment (VC-214 board)
Mode
VTR recording
Signal
Audio signal :
400Hz, –7.5dBs : L or R of AUDIO
terminal
Video signal :
Color bar signal : VIDEO terminal
Measurement Point
AUDIO L terminal and AUDIO R
terminal of IR receiver jig
(Terminated at 47k
)
Measuring Instrument
Audio level meter
Adjustment Page
F
Adjustment Address
67
Specified Value
Signal level: –7.5 ± 2.0 dBs
Level difference of L and R: Below 2dB
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Connect the audio level meter to the AUDIO L terminal of the
IR receiver jig.
3)
Select page: F, address: 67, change the data and set the 400Hz
audio signal level to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Connect the audio level meter to the AUDIO R terminal of the
IR receiver jig.
6)
Check that the 400Hz audio signal level is within the specified
value. If outside, repeat from step 2).
7)
Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
Page of 127