Read Sony CCD-TR913E / CCD-TR950E Service Manual online
5-39
A
0.67
µ
sec
Center of the luminace line width
Center of the luminace line width
Fig. 5-3-13.
VC-214 BOARD
IC202
1
44
132
89
176
133
45
88
IC001
12
1
25 36
13
48
24
37
C085
8. REC L Level Adjustment (VC-214 board)
Set the recording levels of the REC AFM signal and REC ATF signal.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, or SP/LP will not be discriminated properly. If too
high, color beets will be produced on the self-recording / playback
image.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, or SP/LP will not be discriminated properly. If too
high, color beets will be produced on the self-recording / playback
image.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN910 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
7B to 84
Specified Value
A=11.0 ± 0.7mV
Note:
Do not insert any plug into the AUDIO (R) terminal.
Connection:
1)
1)
Remove C085 (0.01
µ
F, Pin !§ of IC202).
Note:
After completing “REC L Level Adjustment” and “REC C
Current Adjustment”, replace C085 with new parts (1-182-970-
11 CERAMIC CHIP 0.01
Current Adjustment”, replace C085 with new parts (1-182-970-
11 CERAMIC CHIP 0.01
µ
F 10% 25V).
Preparations only for the model without REC switch:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
remote commander of 8mm VCR.)
Adjusting method:
1)
1)
Insert Hi8 ME tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 7B, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
4)
Select page: F, address: 85, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
5)
Select page: F, address: 7C, change the data and set the REC
AFM signal level (A) to the specified value.
AFM signal level (A) to the specified value.
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: F, address: 7C, read the data (D
7C
).
8)
Convert D
7C
to decimal notation, and obtain D
7C
'. (Refer to Table
5-4-1. “Hexadecimal-decimal conversion table” of “5-4. Service
Mode”.)
Mode”.)
9)
Calculate the adjustment data (decimal) from the following
equations (decimal calculation), convert it to a hexadecimal
number, and input each adjustment address.
equations (decimal calculation), convert it to a hexadecimal
number, and input each adjustment address.
Address: 7B
D
7B
' = D
7C
'
Address: 7D
D
7D
' = D
7C
'
Address: 7E
D
7E
' = D
7C
'
Address: 7F
D
7F
' = D
7C
' –68
Address: 80
D
80
' = D
7C
' –68
Address: 81
D
81
' = D
7C
' –68
Address: 82
D
82
' = D
7C
' –68
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
the adjustment remote commander.
10) Write the following data (hexadecimal) in page: F, address: 83
to 84.
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
the adjustment remote commander.
11) Select page: 0, address: 01, and set data: 00.
12) Perform “REC C Current Adjustment”.
12) Perform “REC C Current Adjustment”.
Address
83
84
Data
96
96
Processing after completed adjustment only for the model
without REC switch:
1)
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
Click on the first or last page to see other CCD-TR913E / CCD-TR950E service manuals if exist.