CCD-TR618, CCD-TR618E, CCD-TR718E, CCD-TR728E, CCD-TR818, CCD-TRV49, CCD-TRV49E, CCD-TRV58, CCD-TRV58E, CCD-TRV59E, CCD-TRV68, CCD-TRV78, CCD-TRV78E, CCD-TRV88, CCD-TRV98, CCD-TRV98E - Sony Movie Service Manual (repair manual). Page 122

Read Sony CCD-TR618 / CCD-TR618E / CCD-TR718E / CCD-TR728E / CCD-TR818 / CCD-TRV49 / CCD-TRV49E / CCD-TRV58 / CCD-TRV58E / CCD-TRV59E / CCD-TRV68 / CCD-TRV78 / CCD-TRV78E / CCD-TRV88 / CCD-TRV98 / CCD-TRV98E Service Manual online

5-16
4. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
4-1.  Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 350 ± 30 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
4E to 5D, 61
Note1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note2:
1/4 CCD model: CCD-TR818/TRV68/TRV78/TRV78E/TRV88/
TRV98/TRV98E
Switch setting:
NIGHT SHOT (Lens block) ............................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
A0
Only for 1/4 CCD model, write
down the data.
3
F
A0
00
Only for 1/4 CCD model, set the
data and press PAUSE button.
4
6
01
13
Set the data, and press PAUSE
button.
5
6
01
15
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note3)
7
F
A0
Only for 1/4 CCD model, set the
data that is written down at step
2 and press PAUSE button.
Note3:
The adjustment data will be automatically input to page: F, address:
4E to 5D, 61.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
Turn off the power and turn on
again.
3
Perform “Flange Back
Adjustment (2)”
4-2.  Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
4E to 5D, 61
Note1:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
NIGHT SHOT (Lens block) ............................................ OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
A0
Only for 1/4 CCD model, write
down the data.
3
F
A0
00
Only for 1/4 CCD model, set the
data and press PAUSE button.
4
6
01
13
Set the data, and press PAUSE
button.
5
Place a ND filter on the lens so
that the optimum image is obtain.
6
6
01
29
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note2)
8
F
A0
Only for 1/4 CCD model, set the
data that is written down at step
2 and press PAUSE button.
Note2:
The adjustment data will be automatically input to page: F, address:
4E to 5D, 61.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”.
Page of 127
Display

Click on the first or last page to see other CCD-TR618 / CCD-TR618E / CCD-TR718E / CCD-TR728E / CCD-TR818 / CCD-TRV49 / CCD-TRV49E / CCD-TRV58 / CCD-TRV58E / CCD-TRV59E / CCD-TRV68 / CCD-TRV78 / CCD-TRV78E / CCD-TRV88 / CCD-TRV98 / CCD-TRV98E service manuals if exist.