CCD-TR555, CCD-TR555E - Sony Movie Service Manual (repair manual). Page 124

Read Sony CCD-TR555 / CCD-TR555E Service Manual online

6-28
1-3-3. BRIGHT Adjustment (VC-175 board)
Purpose :
Adjust brightness of EVF screen (appearance)
Adjustment error :
The EVF picture will be close to saturated picture
(white washing) or black compression.
Mode
Adjustment mode (B)
Singal
All black signal
Measurement Point
CN006 pin @º (EVF VG) on
VC-175 board
Measuring  Equipment
Oscilloscope
Adjustment Page
D
Adjustment Address
48
Specification
A=7.2 
±
 0.1Vp-p
Connection
1)
Connect CN006 pin @º and pin 7 (REG GND) using a 3300
resistor (1-249-423-11).
Adjustment Procedure:
Related adjustment items
[White Balance Adjustment]
1-3-4. CONTRAST Adjustment (VC-175 board)
Purpose :
Adjust constrast of the EVF screen.
Adjustment error :
The EVF picture becomes dull (white washing)
or close to saturated image.
Mode
Adjustment mode (A)
Singal
30% all white signal
Measurement Point
CN006 pin @º (EVF VG) on VC-175
board
Measuring  Equipment
Oscilloscope
Adjustment Page
D
Adjustment Address
4B
Specification
A=1.75 
±
 0.1Vp-p (NTSC)
A=1.70 
±
 0.1Vp-p (PAL)
Connection
1)
Connect CN006 pin @º and pin 7 (REG GND) using a 3300
resistor (1-249-423-11).
Adjustment Procedure:
Order
Page
Address
Data
Procedure
1
Set the adjustment mode (B). (See “Video Signal For Adjustment” on page 6-26.)
2
0
01
01
Set the data.  (Preparation)
3
D
48
Change the data until the voltage difference (A) between the inverted waveform's pedestal and
the non-inverted waveform's pedestal satisfies the specification.
4
Press the PAUSE button.
5
Exit the adjustment mode (B). (See “Video Signal For Adjustment” on page 6-26.)
6
0
01
00
Set the data. (End)
Order
Page
Address
Data
Procedure
1
Set the adjustment mode (A). (See “Video Signal For Adjustment” on page 6-25.)
2
0
01
01
Set the data.  (Preparation)
3
D
4B
Change the data until the voltage difference (A) between the 30% all white signal and the
pedestal satisfies the specification.
4
Press the PAUSE button.
5
Exit the adjustment mode (A). (See “Video Signal For Adjustment” on page 6-25.)
6
0
01
00
Set the data. (End)
Fig. 6-1-13.
Fig. 6-1-14.
Page of 127
Display