CPD-G200, CPD-G200P - Sony Monitor Service Manual (repair manual). Page 18

Read Sony CPD-G200 / CPD-G200P Service Manual online

CPD-G200/G200P
4-2
A
312 mm
B
MODE
All mode
234 mm
a    1.8 mm
b    1.8 mm
a
B
A
b
B
A
A
0.20 mm
B
MODE
All mode
0.24 mm
Convergence Rough Adjustment
1.
Enter the white crosshatch signal (white lines on black).
2.
Adjust roughly the horizontal and vertical convergence at
four-pole magnet.
3.
Adjust  roughly HMC and VMC at six-pole magnet.
Convergence Adjustment
Static convergence
1.
Receive the crosshatch of R and B.
2.
Recieve H. STAT and V. STAT by 4 pole magnet.
3.
Recieve the white crosshatch signal.
4.
Recieve HMC and VMC by 6 pole magnet.
5.
Recieve the crosshatch of R and B.
Note: Adjust H. STAT and V. STAT in the beggining by 4 pole
magnet not adjuust them by register immediately.
6.
Insert to TLH correction board and correct H. TILT.
7.
Correct XCV by XCV core.
8.
Correct V. TILT bu TLV-VR.
9.
Adjust Y cross by YCH-VR.
10. Correct to get the most suitable convergence pattern.
When necessary, adjust above mentioned from step 1 to step
10 reiterate.
11. Paint lock TLH corection board, neck assy 4 and 6 pole
magnet.
Convergence Specification
White Balance Adjustment Specification
(1) 9300K
x = 0.283 ± 0.005
y = 0.298 ± 0.005
(2) 5000K
x = 0.346 ± 0.005
y = 0.359 ± 0.005
Vertical and Horizontal Position and Size
Specification
Focus adjustment
Adjust the focus volume 1 and 2 for the optimum focus.
Standard: HMC, VMC ± 0.1 mm (In the center of screen)
B
R
R
B
R
B
B
R
R
B
B
XCV
YCH
TLV
TLH 
Purity Mg
4-pole Mg
6-pole Mg
XCV
YCH
H-Trap
TLH
TLV
4 Pole
6 Pole
<<Neck Assy's Zero Position>>
FBT
Focus volume 1 (V)
Focus volume 2 (H)
Purity