CPD-E430 - Sony Monitor Service Manual (repair manual). Page 2

Read Sony CPD-E430 Service Manual online

CPD-E430 (E)
2
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and from all
exposed metal parts to any exposed metal part having a return to chassis,
must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-
540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital
multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or bat-
tery-operated AC voltmeter. The “limit” indication is 0.75 V, so analog
meters must have an accurate low-voltage scale. The Simpson 250 and
Sanwa SH-63Trd are examples of a passive VOMs that are suitable.
Nearly all battery operated digital multimeters that have a 2 V AC range
are suitable.  (See Fig. A)
After correcting the original service problem, perform the following safety
checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-soldered connec-
tions. Check the entire board surface for solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or con-
tact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and mount-
ing hardware have been replaced. Be absolutely certain that you have
replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors, that
were installed during a previous repair. Point them out to the customer
and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of deterio-
ration. Point them out to the customer and recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend the replace-
ment of any such line cord to the customer.
7. Check the B+ and HV to see if they are specified values. Make sure your
instruments are accurate; be suspicious of your HV meter if sets always
have low HV.
8. Check the antenna terminals, metal trim, “metallized” knobs, screws, and
all other exposed metal parts for AC Leakage. Check leakage as de-
scribed below.
Fig. A. Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
Voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
SAFETY  CHECK-OUT
Page of 79
Display

Click on the first or last page to see other CPD-E430 service manuals if exist.