CHASSIS
SERVICE MANUAL
SPECIFICATIONS
CPD-E430
CRV
AEP Model
Chassis No. SCC-L42G-A
TRINITRON
®
 COLOR COMPUTER DISPLAY
CRT
0.24 mm aperture grille pitch, 90-degree deflection, FD Trinitron
19 inches measured diagonally
Viewable image size
Approx. 365 
×
 274 mm (w/h) (14 
3
/
8
 
×
 10 
7
/
8
 inches) 
18.0" viewing image
Resolution (H:Horizontal, V:Vertical)
Maximum: H: 1920 dots, V: 1440 lines
Recommended: H: 1280 dots, V: 1024 lines
Input signal levels
Video signal:
Analog RGB: 0.700 Vp-p (positive), 75
SYNC signal: H/V separate or composite sync: 
TTL 2 k
, Polarity free
Sync on Green: 0.3 Vp-p (negative)
Standard image area
Approx. 352 
×
 264 mm 
(13 
7
/
8
 
×
 10 
1
/
2
 inches) 
Deflection frequency  (H:Horizontal, V:Vertical)
H: 30 to 96 kHz, V: 48 to 170 Hz
AC input voltage/current
100 to 240 V, 50 – 60 Hz, 2.0 – 1.0 A
Power Consumption
Approx. 135 W
Operating temperature
10 ºC to 40 ºC
Dimensions
Approx. 451 
×
 471 
×
 461 mm (w/h/d)
 (17 
7
/
8
 
×
 18 
5
/
8
 
×
 18 
1
/
4
 inches)
Mass
Approx. 25.5 kg (56 lb 3 oz)
Plug and Play
DDC2B/DDC2Bi
GTF
CPD-E430 (E)
2
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and from all
exposed metal parts to any exposed metal part having a return to chassis,
must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-
540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital
multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or bat-
tery-operated AC voltmeter. The “limit” indication is 0.75 V, so analog
meters must have an accurate low-voltage scale. The Simpson 250 and
Sanwa SH-63Trd are examples of a passive VOMs that are suitable.
Nearly all battery operated digital multimeters that have a 2 V AC range
are suitable.  (See Fig. A)
After correcting the original service problem, perform the following safety
checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-soldered connec-
tions. Check the entire board surface for solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or con-
tact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and mount-
ing hardware have been replaced. Be absolutely certain that you have
replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors, that
were installed during a previous repair. Point them out to the customer
and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of deterio-
ration. Point them out to the customer and recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend the replace-
ment of any such line cord to the customer.
7. Check the B+ and HV to see if they are specified values. Make sure your
instruments are accurate; be suspicious of your HV meter if sets always
have low HV.
8. Check the antenna terminals, metal trim, “metallized” knobs, screws, and
all other exposed metal parts for AC Leakage. Check leakage as de-
scribed below.
Fig. A. Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
Voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
SAFETY  CHECK-OUT
CPD-E430 (E)
3
WARNING!!
NEVER TURN ON THE POWER IN A CONDITION IN WHICH THE
DEGAUSS COIL HAS BEEN REMOVED.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY SHADING AND MARK 
¡
 ON THE
SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE
PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE
THESE COMPONENTS WITH SONY PARTS WHOSE PART NUM-
BERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLE-
MENTS PUBLISHED BY SONY. CIRCUIT ADJUSTMENTS THAT
ARE CRITICAL FOR SAFE OPERATION ARE IDENTIFIED IN THIS
MANUAL. FOLLOW THESE PROCEDURES WHENEVER CRITI-
CAL COMPONENTS ARE REPLACED OR IMPROPER OPERA-
TION IS SUSPECTED.
CPD-E430 (E)
4
POWER  SAVING  FUNCTION
This monitor meets the power-saving guidelines set by VESA, TCO’99, 
and 
E
NERGY 
S
TAR. If no signal is input to the monitor from your 
computer, the monitor will automatically reduce power consumption as 
shown below.
*
1
When your computer enters power saving mode, NO SIGNAL appears 
on the screen. After a few seconds, the monitor enters power saving 
mode.
*
2
“Deep sleep” is power saving mode defined by the Environmental 
Protection Agency. 
Power mode
Power consumption
!
 (power) 
indicator
normal operation
 135 W
green
active off*
1
(deep sleep)*
2
 3 W
orange
Page of 79
Display

Download Sony CPD-E430 Service Manual (Repair Manual)

Here you can read online and download Sony CPD-E430 Service Manual in PDF. CPD-E430 service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony CPD-E430 Monitor. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.