4-2. PRINTED WIRING BOARDS AND
SCHEMATIC DIAGRAMS INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50WV or less
are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise speciÞ ed.
All resistors are in ohms. KΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating electrical
power, is as follows:
are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise speciÞ ed.
All resistors are in ohms. KΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating electrical
power, is as follows:
Pitch : 5mm
Rating
electrical
power
:
1
/
4
W
1
/
4
W in resistance,
1
/
10
W and
1
/
8
W in chip resistance.
: nonß ammable resistor.
: fusible resistor.
: internal component.
: panel designation and adjustment for repair.
All variable and adjustable resistors have characteristic curve B, unless
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibillity.
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibillity.
: B+line.
: B-line. (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
4-1. CIRCUIT BOARDS LOCATION
RESISTOR
: RN METAL FILM
: RC SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW NONFLAMMABLE WIREWOUND
: RS NONFLAMMABLE METAL OXIDE
: RB NONFLAMMABLE CEMENT
:
: RN METAL FILM
: RC SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW NONFLAMMABLE WIREWOUND
: RS NONFLAMMABLE METAL OXIDE
: RB NONFLAMMABLE CEMENT
:
ADJUSTMENT RESISTOR
COIL
: LF-8L MICRO INDUCTOR
: LF-8L MICRO INDUCTOR
The components identiÞ ed by shading and
!
symbol are critical for safety. Replace
only with part number speciÞ ed.
The symbol
indicates a fast operating fuse and is displayed on the component
side of the board. Replace only with fuse of the same rating as marked.
Les composants identiÞ es per un trame et une marque
!
sont critiques pour la
securite. Ne les remplacer que par une piece portant le numero speciÞ e.
Le symbole
indique une fusible a action rapide. Doit etre remplace par une
fusible de meme yaleur, comme maque.
The components identiÞ ed by X in this basic schematic diagram
have been carefully factory-selected for each set in order to
satisfy regulations regarding X-ray radiation. Should replacement be
necessary, replace only with the value originally used.
have been carefully factory-selected for each set in order to
satisfy regulations regarding X-ray radiation. Should replacement be
necessary, replace only with the value originally used.
When replacing components identiÞ ed by Y, make the necessary
adjustments as indicated. If the results do not meet the speciÞ ed value,
change the component identiÞ ed by X and repeat the adjustment until
the speciÞ ed value is achieved. (See Page 10)
adjustments as indicated. If the results do not meet the speciÞ ed value,
change the component identiÞ ed by X and repeat the adjustment until
the speciÞ ed value is achieved. (See Page 10)
When replacing the parts listed in the table below, it is important to
perform the related adjustments.
perform the related adjustments.
CAPACITOR
: TA TANTALUM
: PS STYROL
: PP POLYPROPYLENE
: PT MYLAR
: MPS METALIZED POLYESTER
: MPP METALIZED POLYPROPYLENE
: ALB BIPOLAR
: ALT HIGH TEMPERATURE
: ALR HIGH RIPPLE
: TA TANTALUM
: PS STYROL
: PP POLYPROPYLENE
: PT MYLAR
: MPS METALIZED POLYESTER
: MPP METALIZED POLYPROPYLENE
: ALB BIPOLAR
: ALT HIGH TEMPERATURE
: ALR HIGH RIPPLE
SECTION 4: DIAGRAMS
Part Replaced ( )
HV ADJ
RV501
Part Replaced ( )
D Board
T501, IC501, RV501, R540,
R541, R542, R544, R564, R567,
R568, C532, C534, C539, C553,
C554, C555, C556, C558, C561
R541, R542, R544, R564, R567,
R568, C532, C534, C539, C553,
C554, C555, C556, C558, C561
HV Regulator
Circuit
Circuit
D Board
T501, R510, R543, R547, R549,
R552, R595, D515, D517, C540,
C542, C544, IC607, IC901, C951
R552, R595, D515, D517, C540,
C542, C544, IC607, IC901, C951
HV HOLD
DOWN Circuit
DOWN Circuit
D Board
T501, R545, R546, R548, R550,
R596, R934, C535, C541, IC605,
IC607, IC901
R596, R934, C535, C541, IC605,
IC607, IC901
Beam Current
Protector Circuit
Protector Circuit
REFERENCE INFORMATION
A Board
H1 Board