CPD-E240 - Sony Monitor Service Manual (repair manual). Page 13

Read Sony CPD-E240 Service Manual online

— 14 —
CPD-E240
4-2.  PRINTED WIRING BOARDS AND 
SCHEMATIC DIAGRAMS INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50WV or less 
are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise speciÞ ed.
All resistors are in ohms.  KΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating electrical 
power, is as follows: 
Pitch : 5mm 
 
 
 
   Rating 
electrical 
power 
1
/
 4 
W
1
/
 4 
W in resistance, 
1
/
10 
W and 
1
/
 8 
W in chip resistance.
 : nonß ammable resistor.
 : fusible resistor.
 : internal component.
 : panel designation and adjustment for repair.
All variable and adjustable resistors have characteristic curve B, unless 
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibillity.
: B+line.
: B-line.  (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
4-1. CIRCUIT BOARDS LOCATION
RESISTOR                      
: RN        METAL FILM
: RC        SOLID
: FPRD   NONFLAMMABLE CARBON
: FUSE   NONFLAMMABLE FUSIBLE
: RW       NONFLAMMABLE WIREWOUND
: RS        NONFLAMMABLE METAL OXIDE
: RB        NONFLAMMABLE CEMENT
       ADJUSTMENT RESISTOR
COIL      
: LF-8L   MICRO INDUCTOR
The components identiÞ ed by shading and 
!
 symbol are critical for safety. Replace 
only with part number speciÞ ed. 
The symbol 
 indicates a fast operating fuse and is displayed on the component 
side of the board. Replace only with fuse of the same rating as marked.
Les composants identiÞ es per un trame et une marque 
!
 sont critiques pour la 
securite.  Ne les remplacer que par une piece portant le numero speciÞ e.
Le symbole 
 indique une fusible a action rapide. Doit etre remplace par une 
fusible de meme yaleur, comme maque.
The components identiÞ ed by X in this basic schematic diagram 
have been carefully factory-selected for each set in order to 
satisfy regulations regarding X-ray radiation. Should replacement be 
necessary, replace only with the value originally used.
When replacing components identiÞ ed by Y, make the necessary 
adjustments as indicated.  If the results do not meet the speciÞ ed value, 
change the component identiÞ ed by X and repeat the adjustment until 
the speciÞ ed value is achieved. (See Page 10)
When replacing the parts listed in the table below, it is important to 
perform the related adjustments.
CAPACITOR
: TA        TANTALUM
: PS        STYROL
: PP        POLYPROPYLENE
: PT        MYLAR
: MPS     METALIZED POLYESTER
: MPP     METALIZED POLYPROPYLENE
: ALB      BIPOLAR
: ALT      HIGH TEMPERATURE
: ALR      HIGH RIPPLE
SECTION 4: DIAGRAMS
Part Replaced (    ) 
HV ADJ
RV501
Part Replaced (    ) 
D Board   
T501, IC501, RV501, R540,
R541, R542, R544, R564, R567,
R568, C532, C534, C539, C553,
C554, C555, C556, C558, C561
HV Regulator
Circuit
D Board   
T501, R510, R543, R547, R549,
R552, R595, D515, D517, C540,
C542, C544, IC607, IC901, C951  
HV HOLD
DOWN Circuit 
D Board   
T501, R545, R546, R548, R550,
R596, R934, C535, C541, IC605,
IC607, IC901  
Beam Current
Protector Circuit
REFERENCE INFORMATION
A Board
H1 Board
D Board
Page of 60