CPD-E215E, CPD-E220, CPD-E220E (serv.man4) - Sony Monitor Service Manual (repair manual). Page 15

Read Sony CPD-E215E / CPD-E220 / CPD-E220E (serv.man4) Service Manual online

CPD-E220/E215E/E220E
2-3
2-5. H  BOARD  REMOVAL
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in the
direction of the arrow 
C
.
HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t scratch the surface of anode-caps with sharp shaped
material!
2
Don’t press the rubber hardly not to damage inside of anode-
caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
A
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
B
.
a
b
c
Anode Button
H board
H bracket
4
Menu button
Cussion
Bezel assembly
Picture tube
5
Claw
3
Screw
(+BVTP 4 x 16)
1
2
Page of 44
Display