CPD-E200E - Sony Monitor Service Manual (repair manual). Page 18

Read Sony CPD-E200E Service Manual online

CPD-E200E
4-2
Convergence Rough Adjustment
1.
Enter the white crosshatch signal (white lines on black).
2.
Adjust roughly the horizontal and vertical convergence at
four-pole magnet.
3.
Adjust  roughly HMC and VMC at six-pole magnet.
Convergence Adjustment
(1) Static convergence
1.
Receive the crosshatch of R and B.
2.
Adjust H. STAT and V. STAT by 4 pole magnet.
3.
Recieve the white crosshatch signal.
4.
Adjust HMC and VMC by 6 pole magnet.
5.
Recieve the crosshatch of R and B.
Note: Adjust H. STAT and V. STAT in the beggining by 4 pole
magnet not adjuust them by register immediately.
6.
Insert to TLH correction board and correct H. TILT.
7.
Correct XCV by XCV core.
8.
Correct V. TILT by TLV-VR.
9.
Adjust Y cross by YCH-VR.
10. Correct to get the most suitable convergence pattern.
When necessary, adjust above mentioned from step 1 to step
9 reiterate.
11. Paint lock TLH corection board, neck assy 4 and 6 pole
magnet.
B
R
R
B
R
B
B
R
R
B
B
XCV
YCH
TLV
TLH 
Purity Mg
4-pole Mg
6-pole Mg
XCV
YCH
H-Trap
TLH
TLV
4 Pole
6 Pole
<<Neck Assy's Zero Position>>
Purity
(2) Digital Convergence
Convergence (Low) Mode
1.
Adjust the H. STAT and V. STAT with "HSTAT" and
"VSTAT".
A. Horizontal Convergence
Adjust each misconvergence point in sequence.
B. Vertical Convergence
CBH-T-L-LO
9
5
10
18
2
20
12
6
17
1
19
11
CBH-T-R-LO
MBH-T-R-LO
APH-R-LO
MBH-B-R-LO
CBH-B-R-LO
MBH-T-L-LO
APH-L-LO
MBH-B-L-LO
CBH-B-L-LO
YBH-T-LO
HSTAT
YBH-B-LO
2.
Repeat the procedure of A and B so that the convergence of
the entire screen is within the specification.
Convergence (Hight) Mode
1.
Adjust the H. STAT and V. STAT with "HSTAT-HI" and
"VSTAT-HI".
A. Horizontal Convergence
CCV-T-L-LO
13
7
14
22
4
24
16
8
21
3
23
15
CCV-T-R-LO
MCV-T-R-LO
XBV-R-LO
MCV-B-R-LO
CCV-B-R-LO
MCV-T-L-LO
XBV-L-LO
MCV-B-L-LO
CCV-B-L-LO
V STAT-T-LO
VSTAT
V STAT-B-LO
Adjust each misconvergence point in sequence.
CBH-T-L-HI
9
5
10
18
2
20
12
6
17
1
19
11
CBH-T-R-HI
MBH-T-R-HI
APH-R-HI
MBH-B-R-HI
CBH-B-R-HI
MBH-T-L-HI
APH-L-HI
MBH-B-L-HI
CBH-B-L-HI
YBH-T-HI
HSTAT-HI
YBH-B-HI
Adjust each misconvergence point in sequence.
Page of 45