CPD-420GS - Sony Monitor Service Manual (repair manual). Page 13

Read Sony CPD-420GS Service Manual online

— 13 —
CPD-420GS
2-4.  PICTURE TUBE REMOVAL
 Turn up one side of the rubber cap in
the direction indicated by arrow 
.
 When one side of the rubber cap sepa-
rates from the anode button, the anode-
cap can be removed by turning the rub-
ber cap and pulling it in the direction of
arrow 
.
 Use your thumb to pull the rubber cap
firmly in the direction indicated by
arrow 
.
HOW TO HANDLE AN ANODE-CAP
REMOVAL OF THE ANODE-CAP
NOTE:   Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
              removing the anode.
REMOVAL PROCEDURES
 Do not use sharp objects which may cause damage to the surface
of the anode-cap.
 Do not squeeze the rubber covering too hard to avoid damaging
the anode-cap. A material fitting called a shatter-hook terminal is
built into the rubber.
 Do not force turn the foot of the rubber cover. This may cause the
shatter-hook terminal to protrude and damage the rubber.
     Demagnetization coil
     Tension spring
     Stand assy
(D board)
     A board
     Neck assy
     Deflection yoke
     Four screws
(Tapping screw 5)
     Anode cap
Cushion
     Picture tube shield
     Two screws
(BVTP 4 x 16)
1
6
9
10
5
4
3
2
7
8
Page of 37
Display

Click on the first or last page to see other CPD-420GS service manuals if exist.