CPD-220AS - Sony Monitor Service Manual (repair manual). Page 14

Read Sony CPD-220AS Service Manual online

CPD-220AS
– 14 –
SECTION  3
SAFETY  RELATED  ADJUSTMENT
Part Replaced (
[
)
RV501
HV ADJ
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
Beam Current Protector Check
Using an external DC Power Supply, applying voltage of
7.00 ± 0.05 V between !] pin of FBT (T501) and GND,
and confirm that the vlotage of both ends C519 is with in
the Voltage range shown below.
• Standard voltage : Less than 3.26 V DC
Check Condition
• Input voltage : 240.0 V AC
• Input signal
: Cross hatch at 64.0 kHz
(VESA 1024 x 768)
• Beam control : CONT : 100 %, BRT : 40 %
B+ Voltage Check
Standard voltage : 150.0 ± 2.0 V DC
Check Condition
• Input voltage : 240.0 ± 2.0 V AC
Note : Use NF power supply or make sure that
distortion factor is 3% or less.
• Input signal
: Cross hatch at 64.0 kHz
• Beam control : CONT : 100 %, BRT : 40 %
HV Regulator
Circuit
HV Protector
Circuit
Beam Current
Protector Circuit
Part Replaced (
]
)
D board IC801, C509, C542,
C548, C802, C814,
C815, R538, R539,
R540, R541, R807,
R822, R823, R824,
RV501, T501 (FBT)
D board IC801, IC904, D511,
D515, C515, C516,
C517, C910, R532,
R533, R534, R535,
R996, T501 (FBT)
• Mounted D board
D board IC901, D596, C519,
C528, C549, C904,
R542, R543, R544,
R545, R939
• Mounted D board
*
Confirm one minute later turning on the power.
HV Protector Circuit Check
Confirm that the HV protector circuit works and CRT
screen disappearing when apply the voltage as shown
below between Cathode of D511 on D board and GND
using an external DC Power Supply.
• Standard voltage  :  35.00
V DC
Check Condition
• Input voltage : 240.0 ± 2.0 V AC
• Input signal
: Cross hatch at 64.0 kHz
(VESA 1024 x 768)
• Beam control : CONT : 100 %, BRT : 40 %
+0.00
–0.10
Page of 42