CPD-120AS
– 15 –
SECTION  4
ADJUSTMENTS
Mechanical
Center
Set the
finger
Connect the communication cable of the computer to the connector located on the D board on the monitor.  Run the service software and
then follow the instruction.
IBM AT Computer
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
2
*The parts above (                ) are necessary for DAS adjustment.
1
3
D-sub
(9 Pin [female])
mini Din
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
Convergence Rough Adjustment
Set DY four-pole magnet to mechanical center
before adjustment.
This should be prime mode.
Landing Rough Adjustment
1.
Enter the full white signal.
2.
Adjust the contrast to the maximum.
3.
Make the screen monogreen.
4.
Reverse the DY, and adjust coarsely the purity magnet so that
a green raster positions in the center of screen.
5.
Moving the DY forward, adjust so that an entire screen be-
comes monogreen.
6.
Adjust the tilt of DY, and fix lightly with a clamp.
Landing Fine Adjustment
1.
Place the set in the Helmholtz coil.
2.
Enter a green signal only.
3.
Degauss the entire screen with hand-degausser.
4.
Attach a wobbling coil to the specified position of CRT neck.
5.
Attach a landing adjuster sensor on the CRT.
6.
Using a landing checker, adjust the DY position, purity, tilt of
DY.
7.
Clamp the DY screw.
Clamping torque: 19 ± 1kgcm (1.9 ± 0.1 N.m)
Convergence Rough Adjustment
1.
Enter the white crosshatch signal.
2.
Adjusut roughly the horizontal and vertical
convergence at four-pole magnet.
3.
Adjusut roughly HMC and VMC at six-pole
magnet.
*
*
1)
Receive R.B. cross-hatch.
2)
Adjust H.STAT nad V.STAT at four-pole magnet.
<4 Pole Magnet>
4
4
1
2
4
4
1
2
B
R
1
2
R
B
B
R
1 2
+
R
B
1
2
B
R
R
B
1 2
+
NECK Assy
6PoleMg
P.S Mg
XBV
DY
CRT
4Pole Mg
Page of 42