CPD-120AS - Sony Monitor Service Manual (repair manual). Page 13

Read Sony CPD-120AS Service Manual online

CPD-120AS
– 13 –
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in the
direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t hurt the surface of anode-caps with shartp shaped material!
2
Don’t press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-5. PICTURE  TUBE  REMOVAL
     A block
2
     Anode cap
1
     Two screws
     (+BVTP 4 x 16)
3
     Stand assy
4
     Neck assy
5
     Deflection yoke
6
     Picture tube
8
     Four screws
     (Tapping screw 5)
7
     Demagnetization coil
9
     Tension spring
10
     Two degaussing coil holders
11
     Two degaussing coil holders
12
Cushion
a
b
c
Anode Button
Page of 42