DVP-NS758HP - Sony DVD Service Manual (repair manual). Page 2

Read Sony DVP-NS758HP Service Manual online

– 2 –
DVP-NS758HP
SAFETY CHECK-OUT
1. Check the area of your repair for unsoldered or poorly-soldered
connections. Check the entire board surface for solder splashes
and bridges.
2. Check the interboard wiring to ensure that no wires are “pinched”
or contact high-wattage resistors.
3. Look for unauthorized replacement parts, particularly transis-
tors, that were installed during a previous repair.  Point them
out to the customer and recommend their replacement.
4. Look for parts which, though functioning, show obvious signs
of deterioration. Point them out to the customer and recommend
their replacement.
5. Check the line cord for cracks and abrasion.
Recommend  the  replacement  of  any  such  line  cord  to  the
customer.
6. Check the B+ voltage to see it is at the values specified.
7. Check the antenna terminals, metal trim, “metallized” knobs,
screws, and all other exposed metal parts for AC leakage. Check
leakage as described below.
WARNING!!
WHEN SERVICING, DO NOT APPROACH THE LASER EXIT WITH
THE  EYE  TOO  CLOSELY.  IN  CASE  IT  IS  NECESSARY  TO
CONFIRM  LASER  BEAM  EMISSION,  BE  SURE  TO  OBSERVE
FROM A DISTANCE OF MORE THAN 25 cm FROM THE SURFACE
OF THE OBJECTIVE LENS ON THE OPTICAL PICK-UP BLOCK.
CAUTION:
The use of optical instrument with this product will increase eye
hazard.
CAUTION
Use of controls or adjustments or performance of procedures  other
than  those  specified  herein  may  result  in  hazardous  radiation
exposure.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK    OR DOTTED LINE WITH
MARK    ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST  ARE  CRITICAL  TO  SAFE  OPERATION.  REPLACE  THESE
COMPONENTS  WITH  SONY  PARTS  WHOSE  PART
NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLE-
MENTS PUBLISHED BY SONY.
After correcting the original service problem, perform the following safety
checks before releasing the set to the customer:
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from  all  exposed  metal  parts  to  any  exposed  metal  part  having  a
return to chassis, must not exceed 0.5mA (500 microamperes). Leak-
age current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC volmeter. The “limit” indication is 0.75V,
so analog meters must have an accurate low voltage scale. The
Simpson 250 and Sanwa SH-63Trd are examples of a passive
VOM  that  is  suitable.  Nearly  all  battery  operated  digital
multimeters that have a 2V AC range are suitable. (See Fig. A)
Unleaded solder
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size.)
 : LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40°C higher than
ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to about
350°C
Caution: The printed pattern (copper foil) may peel away if the
heated tip is applied for too long, so be careful!
• Strong viscosity
Unleaded solder is more viscous (sticky, less prone to flow) than
ordinary solder so use caution not to let solder bridges occur such
as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may also
be added to ordinary solder.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE 
 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES  POUR  LA  SÉCURITÉ  DE  FONCTIONNEMENT.  NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT  LES  NUMÉROS  SONT  DONNÉS  DANS  CE  MANUEL  OU
DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
To Exposed Metal
Parts on Set
0.15    F 
AC 
Voltmeter
(0.75 V)
Earth Ground
Fig.A. Using an AC voltmeter to check AC leakage.
1.5k 
Ω
Page of 52
Display