— 54 —
The disc is stopped by the portion 
A
 of the center  guide assy. At the same time, 
the loading guide (R) and guide frame (R) assy are moved up to the topmost-end 
again by the extension spring. (arrow mark 
2
) The disc is supported by the three 
points of the tip of the loading guide (R), the portion 
A
 of the door block assy and 
the center guide. (arrow mark 
1
)
The gear (A) (cam drive motor side) rotates in the direction of the arrow mark 
1
.
The control gear (F) and control gear (R) start rotating in the 
directions of the arrow mark 
5
 respectively (arrow marks 
2
 to 
4
via loading gear (B) (cam drive motor side), chuck gear (C) and 
chuck gear (D).
As the timing belt is stopped, 
the cam drive motor (dc motor) 
starts rotation. 
The portion 
G
 of the guide frame (R) assy 
is detected by PH221 of the LS-55 board 
that starts rotation of the loading motor 
(dc motor)
PH261 on the CS-57 board detects from the 
cam groove inside the control gear (F) that 
the control gear (F) rotates by 180˚ that 
stops the cam drive motor (dc motor).
FIG.45
FIG.44
FIG.46
FIG.47
FIG.45
FIG.48
FIG.49
J
The loading gear (E) rotates in the direction of the arrow mark 
5
 
via loading gear (B) (loading motor side), loading gear (C) and 
loading gear (D) (arrow marks 
2
 to 
4
)
The timing belt rotates in the direction of the arrow mark 
q;
 via 
the three link gears and pulley (A) (arrow marks 
6
 to 
9
).
The gear (A) (loading motor side) rotates in the direction of the arrow mark 
1
.
Disc is pinched by the loading guide (R) and the center guide so that 
the disc is transported in the direction of the arrow mark 
2
 while 
rotating in the direction of the arrow mark 
1
.
The loading guide (R) and guide frame (R) assy move down 
again as they are opened by the disc during transportation 
of the disc. (arrow mark 
3
)
PH221 of the LS-55 board detects the portion 
G
 of 
the guide frame (R) assy that stops the loading motor. 
The timing belt is stopped accordingly.