6.
Set the unit to the TELE end.
7.
Aligning the function lever with the screw holes of preset ring assy, push the function lever to the preset ring assy.
8.
Fix it with two screws.
Note:
Be careful for function lever not to come off the aperture operation pin.
9.
Apply the adhesive bond (B-10) to heads of screws (two locations).
10. Hook the main spring guide side of main spring.
Function Lever
Aperture Operation Pin
Preset Ring Assy
Push the function lever
to the preset ring assy
Set the unit to
TELE end.
Apply the adhesive
bond (B-10)
Main Spring
Main Spring Guide
Main Spring