SAL50M28 - Sony Digital Camera Service Manual (repair manual). Page 34

Read Sony SAL50M28 Service Manual online

HELP
SAL50M28 (MACRO 2.8/50) (50mm F2.8 Macro)
HELP36
Adhesive bond (B-10): J-6082-612-A
1.
Install the aperture blades one by one, and put the first blade on the 7th one finally.
2.
Apply the adhesive bond (B-10) to three points for 5 to 10mm of width after completing aperture diameter adjustment.
Apply the adhesive bond (B-10)
(Three points for 5-10 mm)
Aperture Blade
Unit (7)
Aperture Hold
Ring
7
1
Page of 65