1.
Set the main unit assembly to the infinity end and insert counterclockwise the helicoids male as far as it goes.
2.
Align the round mark on the filter screw frame with the concave at the side of the round mark on the outer tube.
3.
Install the lens unit assy to the main unit assy, aligning the driving wheel pin with the cut portion (working part of driving wheel pin).
Note 1:
Insert three projections of rear group assy in three grooves of vertical group cylinder.
Note 2:
Insert three projections of outer tube in three grooves of focus ring assy.
4.
Tighten with three screws.
Note:
Install screws in the center of oblong holes of filter screw frame.
Helicoid Male
Screw
Vertical 
Groove 
Cylinder
Cut portion 
(working part of driving wheel pin)
Round mark 
(Outer Tube)
Lens Unit Assy
Concave
Round mark 
(Filter Screw Frame)
Driving wheel pin
Projection 
(Outer Tube)
Projection 
(Rear Group Assy)
Groove 
(Focus Ring Assy)
Vertical groove
Oblong hole of Filter Screw Frame
Main Unit Assy