SAL50F14 (1.4/50) (50mm F1.4)
HELP05
Attach the signal PC board to the rear light shield barrel.
Note:
Be careful not to tighten the two screws too much shown in the figure.
HELP06
Adhesive bond (B-40): J-6082-614-A
1.
Attach the rear light shield barrel, and apply the adhesive bond (B-40) to the three screws and tighten them as shown in the figure.
2.
Check that the preset ring moves smoothly.
HELP07
Adhesive bond (LOCTITE 460) (Note)
Note:
Use adhesive bond (LOCTITE 460) or an equivalent article.
Don’t use what becomes white after drying like a quick-drying glue.
Grease (G-85):
J-6082-626-A
Anti-diffusion agent (A-20): J-6082-611-A
1.
Apply the adhesive bond (LOCTITE 460) to the stopper screw, and attach it to the lens mount riveting block.
2.
Apply the grease (G-85) and anti-diffusion agent (A-20) to the instruction part of the lens mount riveting block.
3.
After attaching the lens mount riveting block, check the operation of the iris feather unit.
And check the operation of the coupler by turning the helicoid assembly.
Rear Light Shield Barrel
Signal PC Board
Two screws
Rear Light Shield Barrel
Apply the adhesive bond (B-40) (3 areas)
Apply the adhesive bond (LOCTITE 460)
Lens Mount Riveting Block
Apply the anti-diffusion agent (A-20)
Apply the grease (G-85) (3 areas)
Page of 45