Read Sony SAL500F80 Service Manual online

4-19
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
2)
Turn the focusing knob of the flange back tester so that the dial gauge indicates “44.57 mm”.
3)
Turn the helicoid unit of the checking lens until the image is the sharpest.
4)
Mark the scrape line to the focus connect ring at the same position (infinity position) as the index line on the fixed holding tube
marked in step 3) of the preparation.
Fig.4-3-4
5)
Remove the outer barrel assy, gear block, filter and mount block.
6)
Align the infinity position of the focus scale plate with the index line marked in step 4), and affix it to the focus connect ring.
Fig.4-3-5
7)
Affix the two focus scale plate set tapes to both ends of the focus scale plate.
Outer Barrel Assy
Mark the Scrape Line
(infinity position)
Index Line marked in step 3)
Focus Connect Ring
Focus Scale Plate
Scrape line marked in step 4)
Focus Connect Ring