SAL500F80 - Sony Digital Camera Service Manual (repair manual). Page 40

Read Sony SAL500F80 Service Manual online

4-14
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
4-2-2. Optical Axis Adjustment
Equipment
• Flange Back Tester
• A-mount Attachment
• Flange Back Gauge (43.50mm)
• Adhesive bond (B-10)
Note:
Use the collimator (1500 mm or longer)
Adjusting Method
1)
Disassemble or assemble the checking lens into the state of Fig.4-2-5.
Fig.4-2-5
Focus Rubber Ring