SAL24F20Z - Sony Digital Camera Service Manual (repair manual). Page 14

Read Sony SAL24F20Z Service Manual online

4-1
SAL24F20Z (Distagon 2/24 ZA T * SSM) (Distagon T * 24mm F2 ZA SSM)
Note:
  After the service repair, perform the adjustments referring to this section.
4-1. PREPARATIONS
4-1-1. List of Service Tools and Equipments
Variable Transformer (Output voltage: AC 100 V) (Note 3) 
Camera (One of DSLR-A700, SLT-A37/A57/A58/A65/A77/A99)
Memory Card
Screen (Art paper) 
Tape Measure 
Plane Mirror (For SLRs) 
Adhesive bond (B-10): J-6082-612-A 
Lens Adjustment Program (ACSSM-S-VerX.XX.zip) 
Color Calculator 2
Note:
  Acquire the Lens Adjustment Program and Color Calculator 2 from the each HQ.
J-14
J-1
J-9
J-7
J-2
J-4
J-6
J-5
J-8
J-3
20
30
40
50
60
70
80
90
0
10
J-10
J-11
J-12
J-13
Personal computer
(Note 1)
Luminance box
J-6082-581-A
AE master lens
J-6082-597-A
1000 mm Collimator
110V: J-6082-604-A
240V: J-6082-604-B
(Note 2)
Lens test projector
J-6082-605-A
(Note 3)
Flange back tester
J-6082-606-A
A-mount
attachment
J-6082-607-A
Flange back gauge
(43.50 mm)
J-6082-608-A
Finished
Inspection
JIG
J-6082-710-A
(Note 4)
M-BOX JIG
J-6082-722-A
(Note 5)
Chip-A for universal
wrench
J-6082-609-1
Universal
wrench
J-6082-609-A
Chip-B for universal
wrench
J-6082-609-2
Chip-C for
Universal Wrench
J-6082-609-3
Fig. 4-1-1
Note 1:
  Personal Computer (PC)
(Color Calculator 2 installed) 
OS: Windows 
Vista/7
MEMORY: 
40 M Byte or more recommended 
Hard disk free area: 15 M Byte or more recommended 
USB terminal: 
Standard equipment 
Graphics: 
32,000 colors or more recommended VGA monitor








Note 2:
  Attach the chart to the 1000 mm collimator as shown in Fig. 4-1-2.
Align the marks
1000 mm collimator
Chart
 Fig. 
4-1-2
Note 3:
  Connect the variable transformer (Output voltage: AC 100 V) to the lens test projector.
Note 4:
  For connection of Finished Inspection JIG II, refer to  4-7-2. Connection of Finished Inspection JIG II/Half Completion JIG and Startup of Lens 
Adjustment Program (ActuatorCheckerSSM) .
Note 5:
  M-Box jig is available in use for Finished Inspection jig II (J-6082-710-A).
Note 6:
  Modify the zoom retainer tube block as follows to make the Half Completion JIG.
Equipment
Finished Inspection JIG 
(J-6082-710-A)
D-sub 9pin Cable (Commercially available)
1. Preparation
1)  Cut the one side of the D-sub 9pin cable.
2)  Solder 1-8 pins with the SSM PC BOARD ASSY as shown in Fig 4-1-3.
1 2 3
6 7 8
4 5
8 7 6 5 4 3 2 1
 Fig. 
4-1-3

4. ADJUSTMENTS
Ver. 1.2 2015.07
Page of 51
Display