SAL1855 - Sony Digital Camera Service Manual (repair manual). Page 13

Read Sony SAL1855 Service Manual online

HELP
SAL1855 (DT 3.5-5.6/18-55 SAM) (DT 18-55mm F3.5-5.6 SAM)
HELP10
1.
Set the zoom to the TELE end and insert the 2nd lens barrel block, aligning the grooves with the projections at three locations.
Note:
Align the aperture lever with the ZF flexible PWB.
2.
Set the zoom to the WIDE end, and the 2nd lens barrel block is pulled in and fixed.
Note:
If the zoom is set to the TELE end, the 2nd lens barrel block will be dislocated. Therefore, do not set the zoom to the TELE
end.
3.
Install the Tele stopper.
Note:
Install it in the state that the zoom is set to a position other than the TELE end.
4.
Push the zoom to the TELE end and tighten it with one screw.
2nd Lens Barrel Block
ZF Flexible PWB
Aperture Lever
Set to the WIDE end.
Set to the TELE end.
Projection
Projection
Projection
The 2nd lens barrel block 
is pulled in and fixed.
Groove
Tele Stopper
Tele Stopper
Push to the TELE end