4-13
SAL18135 (3.5-5.6/18-135 SAM) (DT18-135mm F3.5-5.6 SAM)
4.  Confirm that all of the items are set.
 
 Fig. 
4-7-5
5.  Click the [OK] to close the SETUP window.
4-7-4. About Inspection Procedure of Lens Adjustment Program (ActuatorCheckerSAM)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the 
inspection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one. 
4-8. FINISHED ADJUSTMENT/INSPECTION
Equipment (Only the specific equipment is listed.)
•  Adhesive Bond (B-10)
4-8-1. Preparation
1.  Connect the inspecting lens to the equipment. (Refer to  4-7-2. Connection of Finished Inspection JIG II and Startup of Lens Adjust-
ment Program (ActuatorCheckerSAM) .)
2.  Start up the lens adjustment program (ACSAM-S-VerX.XX.exe).
3.  Click [Setup] and perform the initial setting. (Refer to  4-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSAM) .)
4-8-2. Completion  Adjustment/Inspection  Item
1. Adjustment/Inspection Method
1) Click 
[Start[Ent]].
2)  Follow the instruction on the menu.
2. Adjustment/Inspection Item
1)  Check AF/MF Switch
2)  Check LVDD1 Consumption Current
3)  Adjust Focus Potentio
4) Zoom 
Pattern
5) Adjust PI
6)  Focus Load FB
7)  Check Focus Potentio
8)  Focus Motor Curent
9) Stopping 
Accuracy
10) Write 
SB
Fig. 4-8-1
Note: 
 The following item is not adjusted automatically in the case of Adjustment/Inspection by clicking [Start[Ent]].
11) Search Zoom Adj
4-8-3. Zoom Pattern Inspection
1. Preparation
1)  Disassemble or assemble the lens to be inspected to set it in the state of Fig. 4-8-2.
Note:
  Disassembling the lens is not required during checking.
Focus Rubber Ring (8948)
MF Ring Tape
 Fig. 
4-8-2
2. Checking/Adjustment Method
1)  Set the zoom to the TELE end. At this time, confirm that the brush and the LF-145 flexible board pattern are in the state of Fig4-8-3.
2)  Unscrew the screw securing the zoom brush to adjust the brush position.
Note:
  Adjust the brush position so that the notch A of the LF-145 flexible board pattern matches the contact point B of the brush. (The second pattern 
from the top of the brush contacting patterns)
Cut portion A
(LF-145 FLEXIBLE PWB)
Apply the bond (B-10)
Zoom Brush
Contact portion B
 Fig. 
4-8-3
3)  Click [Inspect zoom pattern] of ACSAM-S.
4)  If the zoom brush is on the TELE adjustment end, the following pop-up window appears.
 Fig. 
4-8-4
5)  Set the zoom to the TELE or WIDE end again and check that the TELE adjustment end is not deviated.
6)  After the adjustment has been completed, apply the bond (B-10) to the screw head. (Refer to Fig.4-8-3.)