SAL135F18Z - Sony Digital Camera Service Manual (repair manual). Page 49

Read Sony SAL135F18Z Service Manual online

4-13
SAL135F18Z (Sonnar 1.8/135 ZA) (Sonnar T
*
 135mm F1.8 ZA)
4-2.
APERTURE DIAMETER CHECK/ADJUSTMENT
4-2-1. Aperture Diameter Check
Equipment
• Luminance Box
• Camera DSLR-A100
• AE Master Lens
• Compact Flash (CF) Card (For image saving)
• Personal Computer (PC)
(Color Calculator 2 installed)
1. Preparations
Note: Confirm the checking lens by complete. (The adjustment of focus brush is completed.)
1)
Install the CF card to the camera.
2)
Set the equipments, camera and master lens as shown in Fig.4-2-1.
Fig.4-2-1
3)
Shoot the images under the following conditions and save them.
Note: Shoot the center of the luminance surface three times with the master lens and checking lens.
Setting of Luminance box:
Luminance:
EV12
Setting of Lens:
Focus:
Infinity end
Setting of Camera:
ISO:
100
Exposure Mode:
M
shutter Speed:
1/125
Aperture:
F5.6
Focus Mode:
MF
Metering:
Center weighted
Preset white balance: Tungsten
D-R:
OFF
Luminance box
 Luminance: EV12
Camera
 ISO: 100
 Exposure Mode: M
 Shutter Speed: 1/125
 Aperture: F5.6
 Focus Mode: MF
 Metering: Center weighted
 Preset white balance: Tungsten
 D-R: OFF
Master lens or checking lens
  Focus: Infinity end
Shoot the center of the luminance surface
Ver. 1.4  2007.12
The changed portions from
Ver. 1.3 are shown in blue.
Page of 79
Display