4-21
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
h
h
h
h
h
4-7-2. Focus Brush Position Adjustment and Pattern Check
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Adhesive bond (B-10)
• Lens Adjustment Program
Note:
Lens Adjustment Program is downloadable from the ESI homepage.
1. Pattern Check
Note:
When the NG (Red) indicator of “Position” lights during checking, does not care about it (It is normal performance).
1)
Turn the focus ring slowly from the near end “Focus Pattern : 1” to the infinity end “Focus Pattern : 19” and check that the value of
“Focus Pattern” change from 1 to 19 continuously.
2)
Turn the focus ring slowly from the infinity end “Focus Pattern : 19” to the near end “Focus Pattern : 1” and check that the value of
“Focus Pattern” change from 19 to 1 continuously.
Fig. 4-7-5
3)
Click the 
[Exit]
 button.
4)
Click the 
[End]
 button to terminate the lens adjustment program.
5)
Turn the POWER switch of the camera to OFF.
Page of 55
Display