SAL1118 - Sony Digital Camera Service Manual (repair manual). Page 51

Read Sony SAL1118 Service Manual online

4-20
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
4-7.
FOCUS BRUSH POSITION AND PATTERN CHECK
Note:
If dialog box of error code appears during the checking or adjustment, check the reason of error referring to page 4-22.
4-7-1. Focus Brush Position Check
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Lens Adjustment Program
Note:
Lens Adjustment Program is downloadable from the ESI homepage.
1. Preparations
1)
Connect the checking lens to the camera.
2)
Start the lens adjustment program “LensAdjustment.exe” referring to “4-1-2. Lens Adjustment Program”.
Fig. 4-7-1
2. Checking Method
1)
Click the 
[Connect]
 button on the lens adjustment program.
Note:
Click the 
[End]
 button to disconnect the USB connection, then lens adjustment program will terminate.
Fig. 4-7-2
2)
Click the 
[Focus]
 button on the lens adjustment program.
3)
Set the zoom position to Wide end and the focus position to infinity end, then check that the OK (Green) indicator of “Position”
lights as shown in Fig. 4-7-3.
Fig. 4-7-3
If the NG (Red) indicator of “Position” lights, then check that Focus Brush Position.
Fig. 4-7-4
4)
Click the 
[Exit]
 button.
5)
Click the 
[End]
 button to terminate the lens adjustment program.
6)
Turn the POWER switch of the camera to OFF.
Ver 1.3  2007.04
Page of 55
Display

Click on the first or last page to see other SAL1118 service manuals if exist.