1-4
NEX-VG900/VG900E_L2
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0 * Zoom operations fault
(Cannot initialize zoom lens.)
Turn power off and turn power on again.
E
6
1
1
1 *
The abnormalities in initialization of the focus
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Turn power off and turn power on again.
E
6
1
3
0
Reset position detection error on the stepper
iris initializing
Refer to “1-8. METHOD OF COPING WITH LENS ERROR”.
E
6
2
0
0 *
Handshake correction function does not work
well. (With PITCH angular velocity sensor
output stopped.)
Turn power off and turn power on again.
E
6
2
0
1 *
Handshake correction function does not work
well. (With YAW angular velocity sensor
output stopped.)
Turn power off and turn power on again.
E
6
2
0
2 * Abnormality of IC for steadyshot.
Turn power off and turn power on again.
E
6
2
0
3 * IC for steadyshot and micro controller com-
munication abnormality among.
Turn power off and turn power on again.
E
6
2
0
4 * Image vibration correction during
handshake function does not work.
Turn power off and turn power on again.
E
6
2
1
0 * Shift lens initializing failure.
Turn power off and turn power on again.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to “1-8. METHOD OF COPING WITH LENS ERROR”.
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to “1-8. METHOD OF COPING WITH LENS ERROR”.
E
6
2
2
0
Abnormality of thermistor.
Refer to “1-8. METHOD OF COPING WITH LENS ERROR”.
E
6
2
3
0
Abnormality of main CPU.
Turn power off and turn power on again.
E
9
1
0
1 * Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
0
2 * Abnormality of flash unit.
Turn power off and turn power on again.
E
9
1
0
3 * Abnormality of flash unit Temperature
detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max
discharge current
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each
output of DC/DC converter on IC4301 of VC-1006 board with the
AC adaptor connected DC JACK (J901).
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing or back up the
flash memory
Check the OneNAND of CPU (IC1301 on the VC-1006 board).
E
9
4
0
1 * Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-1006 board).
E
9
5
0
0 * GPS hardware error
Turn power off and turn power on again.
E
9
6
0
0 * Map area mount error
Turn power off and turn power on again.
E
9
7
0
0 * Projector hardware error
Turn power off and turn power on again.
– ENGLISH –
1-8. METHOD OF COPING WITH LENS ERROR
When lens error is occurred, check the following items.
Lens error codes:
・ E: 61: 30 (Reset position detection error on the stepper iris initializing)
・ E: 62: 11 (Shift lens overheating (Pitch))
・ E: 62: 12 (Shift lens overheating (Yaw))
・ E: 62: 20 (Abnormality of thermistor)
・ E: 62: 11 (Shift lens overheating (Pitch))
・ E: 62: 12 (Shift lens overheating (Yaw))
・ E: 62: 20 (Abnormality of thermistor)
Check items:
1. Replace the lens.
2. Replace the VC-1006 board or IC1301 on the VC-1006 board.
3. Check that the square wave is appeared below points.
1. Replace the lens.
2. Replace the VC-1006 board or IC1301 on the VC-1006 board.
3. Check that the square wave is appeared below points.
・ BODY_VD_LENS (pin 0 of CN5201 or pin 6 of IC5201 on the MT-1002 board)
・ BODY_DATA_LENS (pin qf of CN5201 or pin 4 of IC5203 on the MT-1002 board)
・ LENS_DATA_BODY (pin qd of CN5201 or pin 5 of IC5202 on the MT-1002 board)
・ BODY_DATA_LENS (pin qf of CN5201 or pin 4 of IC5203 on the MT-1002 board)
・ LENS_DATA_BODY (pin qd of CN5201 or pin 5 of IC5202 on the MT-1002 board)
1-9. NOTE ON REPLACEMENT OF MOUNT ADAPTOR (LA-EA3) (SERVICE)
To replace the Adaptor Service, connect this mount to NEX-F3D/F3K/F3Y, and release the specified plug according to the “SERVICE” section of
Adjust Manual.
Adjust Manual.
Note: The Lens can not be detected when this mount is connected to NEX-VG900/VG900E without releasing the specified plug, even if A-Mount Lens is mounted.
Displayed as “F--”