1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-344 BOARD
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Deleting Network Settings
Before replacing the SY-344 board, delete the customer’s network settings.
Perform “NETWROK SETTING RESET” on the DATA tab of the Adjust Manual.
USB Serial No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Imager DRA Data
Extract the imager data from the set before the SY board replacement using “Imager DRA Data Reference” in the DATA tab of the Adjust manual. 
After the SY board has been replaced, write the data extracted from the set before the SY board replacement in the set using “Imager DRA Data Input” 
in the ADJUST tab of the Adjust manual.
Product ID
The unit is shipped after an ID (PRODUCT ID) unique to each model has been written.
This ID is not written to a new replacement board. Enter a unique ID after the board has been replaced.
Start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB SERIAL No. INPUT”.
Setting PRODUCT ID
No PRODUCT ID is set for a new replacement board.
Therefore, if the board is replaced with a new replacement board, a discrepancy with the user-registered PRODUCT ID provided by the customer 
may be generated.
After the board has been replaced with a new replacement board, start Adjust Manual from Adjust Station and execute “PRODUCT ID & USB SE-
RIAL No. INPUT”.
1-2.  PRECAUTION FOR REPLACEMENT OF IMAGER
In this model, the following procedure is required when the imager is replaced.
•  In the case that the imager data can be extracted from the set before the replacement, refer to “Imager DRA Data” in “1-1. PRECAUTION ON 
REPLACING THE SY-344 BOARD”.
•  In the case that the imager data cannot be extracted from the set before the replacement, replace both SY board and imager unit. 
  Capture the data to PC from CD-ROM supplied with the imager unit when it is ordered.
  Write the captured data in the set using “Imager DRA Data Input” in the ADJUST tab of the Adjust manual.
  After all adjustment items have been completed, execute “Phase Detection AF Check” on the SERVICE tab of the Adjust manual.
– ENGLISH –
1-3.  ADDITION OF DESTINATION DATA FILE
If the Destination Data file included in the Adjust manual is old, “DESTINATION DATA WRITE” cannot be executed in some cases.
In that case, download a new Destination Data file from the TISS homepage according to the following procedure.
Note 1:  To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
 
Install the Adjust manual of the DSC-WX50 series in advance.
Note 2:  The actual image may differ from the image shown above.
1)  If the Destination Data file in the Adjust manual in use is old, the window shown in Fig. 1 is displayed.
 
Click the [OK] button.
 Fig. 
1
2)  The Destination Data Write window opens.
 
Check the version of the Destination Data file retained in the Adjust manual.
Destination Ver. window