1-4.  METHOD FOR ADJUSTING THE TEBURE REVISE
Make sure to confirm below after replacing the AS Slider B Assy or the AS Holder Actuator Assy.
(1)  Remove the CV Rear Cover Assy (865), temporally mount the AS Slider Unit (863) mounted with the Imager Sensor, and then set up the camera 
 
body and hold the AS Slider Unit (863) as shown in figure.
 
(2)  Select “Slider Unit Check” of the adjustment software, and then confirm if the result is OK.
(3)  Select “Tebure Revise Adj.” of the adjustment software, and then confirm if the result is OK.
(4)  Mount the AS Slider Unit (863) to the camera.
 
1-5.  METHOD FOR REPLACING THE AS SLIDER B ASSY
Removal Procedure
(1)  Remove the spring.
 
Spring
(2)  Remove the solder on the enamel wires at two places.
 
Solder
Solder
(3)  Remove the flexible board from the AS Slider B Assy.
 
Flexible Board
(4)  Remove two screws.
 
(5)  Remove the AS Unit Holder Ball.
 
AS Unit Holder Ball
(6)  Remove two Ball Bearings.
 
Ball Bearing
Ball Bearing
(7)  Remove two Cap SPs (for Pitch and Yaw).
 
Cap SP
(8)  Remove two Caps (for Pitch and Yaw).
 
Cap
(9)  Remove the AS Slider A Assy.
 
It can be done easily if A is removed beforehand.
 
AS Slider A Assy
A
(10)  Remove the AS Slider B Assy.
 
It can be done easily if B is removed beforehand.
 
AS Slider B Assy
B
(11)  Remove three Ball Bearings.
 
Ball Bearing
Page of 31