DSC-W90 (serv.man5) - Sony Digital Camera Service Manual (repair manual). Page 3

Read Sony DSC-W90 (serv.man5) Service Manual online

— 3 —
DSC-W90_ADJ
• Addition of 
[Read]
[Save]
, and 
[Load]
 buttons
to Angular Velocity Sensitivity Adjustment
&
: Points added portion.
8.
CAMERA Adjustment 7
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
8-1. Precaution before adjustment
(Service manual page 6-28)
Before adjustment, read the following data and record them.
When the SY-169 board is replaced, read out the data before the
replacement, and record them.
Reading out method:
1) Read out the data in Block:11, Page:61, Address:0E10, and
name this as Dp.
2) Read out the data in Block:11, Page:61, Address:0E11, and
name this as Dy.
Note:
The previous data (Dp, Dy) can be read from the SY-
169 board and it can be saved in the PC as a file by
using the Automatic Adjustment Program. (Refer to “8-
4. Angular Velocity Sensor Sensitivity Adjustment”)
: Points changed portion.
8-4.
Angular Velocity Sensor Sensitivity Adjustment
(Service manual page 6-29)
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 7, and the fol-
lowing screen will appear.
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy)
from the SY-169 board.
[Save] button: Saves the previous data (Dp, Dy) in the PC as a
file.
[Load] button: Loads and displays the previous data (Dp, Dy)
from the file saved in the PC.
Note:
The previous data (Dp, Dy) is saved with the file name
“DSC_W90_DpDyData.dat” in the same folder as the
Automatic Adjustment Program.
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
3) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
4) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
(
Page of 4