DSC-W90 (serv.man5) - Sony Digital Camera Service Manual (repair manual)

dsc-w90 (serv.man5) service manual
Model
DSC-W90 (serv.man5)
Pages
4 Few pages! See other manuals at the bottom of the first or last page.
Size
113.74 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SUPPLEMENT-1 ADJUSTMENTS
File
dsc-w90-sm5.pdf
Date

Read Sony DSC-W90 (serv.man5) Service Manual online

SERVICE MANUAL
Auto-ADJ
Ver. 1.1  2007.04
Sony EMCS Co.
9-852-192-81
2007D0500-1
© 2007.4
Published by Kohda TEC
SUPPLEMENT-1
File this supplement with the service manual.
(DI07-003)
• Change of Automatic Adjustment Program
• Change of Destination Data Write
• Addition of 
[Read][Save], and [Load] buttons to Angular
Velocity Sensitivity Adjustment
• Addition of AF Illuminator as a Controllable LED to
LED Check
DSC-W90_ADJ
DSC-W90
— 2 —
DSC-W90_ADJ
• Change of Automatic Adjustment Program
Version of Automatic Adjustment Program has
been changed from Ver_1.0r01 into Ver_1.1r02.
: Points changed portion.
6-1. CAMERA  SECTION  ADJUSTMENTS
1-2.
ADJUSTMENT  PROGRAM
2.
Start of Automatic Adjustment Program
(Service manual page 6-13)
Double-click the application file (DSC-W90 Auto-Adj
Ver_1.1r02.exe), and the Automatic Adjustment Program will start.
3.
Function of Each Button on Main Menu Screen
(Service manual page 6-13)
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-14 will appear. On this screen, select each ad-
justment section.
Fig. 6-1-14
qa
This part indicates the version of Automatic Adjustment Pro-
gram.
• Change of Destination Data Write
: Points changed portion.
1-3.
DESTINATION  DATA  WRITE
2.
Destination Data Write
(Service manual page 6-15)
[Writing method]
1) Select the written destination with the Destination List.
2) Click the [Data Write] button.
3) The writing finishes when the following message is displayed.
3
5
4
7
6
2
1
9
0
8
qa
— 3 —
DSC-W90_ADJ
• Addition of 
[Read]
[Save]
, and 
[Load]
 buttons
to Angular Velocity Sensitivity Adjustment
&
: Points added portion.
8.
CAMERA Adjustment 7
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
8-1. Precaution before adjustment
(Service manual page 6-28)
Before adjustment, read the following data and record them.
When the SY-169 board is replaced, read out the data before the
replacement, and record them.
Reading out method:
1) Read out the data in Block:11, Page:61, Address:0E10, and
name this as Dp.
2) Read out the data in Block:11, Page:61, Address:0E11, and
name this as Dy.
Note:
The previous data (Dp, Dy) can be read from the SY-
169 board and it can be saved in the PC as a file by
using the Automatic Adjustment Program. (Refer to “8-
4. Angular Velocity Sensor Sensitivity Adjustment”)
: Points changed portion.
8-4.
Angular Velocity Sensor Sensitivity Adjustment
(Service manual page 6-29)
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 7, and the fol-
lowing screen will appear.
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy)
from the SY-169 board.
[Save] button: Saves the previous data (Dp, Dy) in the PC as a
file.
[Load] button: Loads and displays the previous data (Dp, Dy)
from the file saved in the PC.
Note:
The previous data (Dp, Dy) is saved with the file name
“DSC_W90_DpDyData.dat” in the same folder as the
Automatic Adjustment Program.
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
3) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
4) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
(
— 4 —
DSC-W90_ADJ
• Addition of AF Illuminator as a Controllable
LED to LED Check
&
: Points added portion.
6-2. SERVICE  MODE
2-2.
SERVICE  MODE
3.
LED Check
(Service manual page 6-36)
Click the [LED Check] button on the SERVICE MODE screen, and
the “LED CHECK” screen will appear.
Using method:
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
*
Page of 4
Display

Download Sony DSC-W90 (serv.man5) Service Manual (Repair Manual)

Here you can read online and download Sony DSC-W90 (serv.man5) Service Manual in PDF. DSC-W90 (serv.man5) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony DSC-W90 (serv.man5) Digital Camera. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.