Read Sony DSC-W90 (serv.man5) Service Manual online
SERVICE MANUAL
Auto-ADJ
Ver. 1.1 2007.04
Sony EMCS Co.
9-852-192-81
2007D0500-1
© 2007.4
Published by Kohda TEC
SUPPLEMENT-1
File this supplement with the service manual.
(DI07-003)
• Change of Automatic Adjustment Program
• Change of Destination Data Write
• Addition of [Read], [Save], and [Load] buttons to Angular
• Change of Destination Data Write
• Addition of [Read], [Save], and [Load] buttons to Angular
Velocity Sensitivity Adjustment
• Addition of AF Illuminator as a Controllable LED to
LED Check
DSC-W90_ADJ
DSC-W90
— 2 —
DSC-W90_ADJ
• Change of Automatic Adjustment Program
Version of Automatic Adjustment Program has
been changed from Ver_1.0r01 into Ver_1.1r02.
been changed from Ver_1.0r01 into Ver_1.1r02.
: Points changed portion.
6-1. CAMERA SECTION ADJUSTMENTS
1-2.
ADJUSTMENT PROGRAM
2.
Start of Automatic Adjustment Program
(Service manual page 6-13)
Double-click the application file (DSC-W90 Auto-Adj
Ver_1.1r02.exe), and the Automatic Adjustment Program will start.
Ver_1.1r02.exe), and the Automatic Adjustment Program will start.
3.
Function of Each Button on Main Menu Screen
(Service manual page 6-13)
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-14 will appear. On this screen, select each ad-
justment section.
screen in Fig. 6-1-14 will appear. On this screen, select each ad-
justment section.
Fig. 6-1-14
qa
This part indicates the version of Automatic Adjustment Pro-
gram.
gram.
• Change of Destination Data Write
: Points changed portion.
1-3.
DESTINATION DATA WRITE
2.
Destination Data Write
(Service manual page 6-15)
[Writing method]
1) Select the written destination with the Destination List.
1) Select the written destination with the Destination List.
2) Click the [Data Write] button.
3) The writing finishes when the following message is displayed.
3
5
4
7
6
2
1
9
0
8
qa
— 3 —
DSC-W90_ADJ
• Addition of
[Read]
,
[Save]
, and
[Load]
buttons
to Angular Velocity Sensitivity Adjustment
&
: Points added portion.
8.
CAMERA Adjustment 7
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
8-1. Precaution before adjustment
(Service manual page 6-28)
(Service manual page 6-28)
Before adjustment, read the following data and record them.
When the SY-169 board is replaced, read out the data before the
replacement, and record them.
When the SY-169 board is replaced, read out the data before the
replacement, and record them.
Reading out method:
1) Read out the data in Block:11, Page:61, Address:0E10, and
1) Read out the data in Block:11, Page:61, Address:0E10, and
name this as Dp.
2) Read out the data in Block:11, Page:61, Address:0E11, and
name this as Dy.
Note:
The previous data (Dp, Dy) can be read from the SY-
169 board and it can be saved in the PC as a file by
using the Automatic Adjustment Program. (Refer to “8-
4. Angular Velocity Sensor Sensitivity Adjustment”)
169 board and it can be saved in the PC as a file by
using the Automatic Adjustment Program. (Refer to “8-
4. Angular Velocity Sensor Sensitivity Adjustment”)
: Points changed portion.
8-4.
Angular Velocity Sensor Sensitivity Adjustment
(Service manual page 6-29)
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 7, and the fol-
1) Click the [Start] button of Camera Adjustment 7, and the fol-
lowing screen will appear.
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy)
[Read] button: Reads and displays the previous data (Dp, Dy)
from the SY-169 board.
[Save] button: Saves the previous data (Dp, Dy) in the PC as a
file.
[Load] button: Loads and displays the previous data (Dp, Dy)
from the file saved in the PC.
Note:
The previous data (Dp, Dy) is saved with the file name
“DSC_W90_DpDyData.dat” in the same folder as the
Automatic Adjustment Program.
Automatic Adjustment Program.
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
at lower left of screen.
3) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
4) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
ates normally.
(
— 4 —
DSC-W90_ADJ
• Addition of AF Illuminator as a Controllable
LED to LED Check
&
: Points added portion.
6-2. SERVICE MODE
2-2.
SERVICE MODE
3.
LED Check
(Service manual page 6-36)
Click the [LED Check] button on the SERVICE MODE screen, and
the “LED CHECK” screen will appear.
the “LED CHECK” screen will appear.
Using method:
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
*