DSC-W620 - Sony Digital Camera Service Manual (repair manual). Page 23

Read Sony DSC-W620 Service Manual online

DSC-W620
3-15
 
To Tele, apply a positive supply voltage (+) 
of DC2.5 V here. 
To retract, apply a positive supply voltage (+) 
of DC2.5 V here.  
22. Install the two screws.
23. Solder the connection.  
24. To test the assembly, apply a voltage of 2.5 V for DC to the zoom motor.
Mirror
Check
Dust check
1. Viewing from the front lens 
No visible dust inside the lens. 
2. Shooting check 
2-1. Shoot the object with following conditions 
- Object should be perfect white high brightness object. (Example; PTB1450 clear chart, etc)  
- Shoot above object from a few centimeters with Pixel; Maximum size and Tele end. 
2-2. Check the image on PC. Image should have no dust. 
Focus Check 
1. Preparation 
- Camera installed re-assemble lens 
- Test camera for comparing  
- Chart (Printed PDF file at the same magnification) 
- Tripod 
- Mirror (ex. CD) 
- Memory Stick 
- PC
2. Setting up to shoot 
2-1. Paste the chart. 
- Chart should be on the flat wall.
- Illuminance level in the chart should be the same.  
- Make the tripod’s height and the center of the chart to the same
  height. 
- Enough space needed for shooting 
2-2. Set up the camera as follows;  
- [P] mode  
- [Maximum] size   
- ISO lowest level  
- Steady Shot [OFF]   
- Flash [OFF]  
2-3. Attach the camera on a tripod.  
2-4. Align the positions of the camera and the chart as follows; 
2-4-1. Set the zoom position of the camera at Wide end.  
2-4-2. Attach the mirror(*) onto the center of the chart.  
(*) The mirror should not tilt on the chart.  