Read Sony DSC-W520 Service Manual online
DSC-W520
3-7
Glued area
Glued area
To Tele, apply a positive supply voltage (+) of
DC2.5 V here.
DC2.5 V here.
1. Set the lens to Tele position.
2. Heat the glued areas of COSMETIC RING up with a heater such as hair dryer.
Pour a solvent such as ethyl alcohol.
Then twist and remove the COSMETIC RING.
Then twist and remove the COSMETIC RING.
3-3. Replacing BARRIER ASSY
Outside
Inside
3. Unlock the two hooks with a thin tool.
4. BARRIER ASSY can be removed.