DSC-W5, DSC-W7 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 28

Read Sony DSC-W5 / DSC-W7 (serv.man3) Service Manual online

6-26
DSC-W5/W7
1-7.
INITIALIZATION OF DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “06: DSC-W5/W15” or “07: DSC-
W7/W17”.
4) Click 
[All]
  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-62 A)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Wait for more than 3 sec.
10) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
Fig. 6-1-62
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6D or 6E or 6F or 78 or 79 page data have been
initialized, the following adjustment needs to be per-
formed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “06: DSC-W5/W15” or “07: DSC-
W7/W17”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-62
B
)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Wait for more than 3 sec.
10) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
B
A
06
06: DSC-W5/W15
07: DSC-W7/W17
Page of 32
Display

Click on the first or last page to see other DSC-W5 / DSC-W7 (serv.man3) service manuals if exist.