Read Sony DSC-W30 / DSC-W40 (serv.man4) Service Manual online
6-6
DSC-W30/W40_ADJ
Fig. 6-1-4
6-1. CAMERA SECTION ADJUSTMENTS
1-1.
PREPARATIONS BEFORE ADJUSTMENTS
1-1-1.
Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).
2) Start up the application for adjustment (SEUS).
Note:
Before perform the adjustment, set the following data.
1) Select page: 40, address: 38 and set data: 00.
1) Select page: 40, address: 38 and set data: 00.
Fig. 6-1-3
Pattern box
Front of the lens
L = About 11 cm
L
Camera
PC
(The SEUS must be installed in the PC.)
OS: Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
VIDEO Adjustment
Osilloscope
Terminated
75
75
Ω
AC IN
AC power adaptor
AC-LS5
(1-479-284-51)
AC-LS5
(1-479-284-51)
To USB
connector
connector
To AV OUT jack (Note)
Note: Do not connect the A/V cable when
performing the LCD Adjustment.
performing the LCD Adjustment.
HASP Key
To USB connector
USB cable
(1-829-868-41)
(1-829-868-41)
Audio (Black)
Video (yellow)
Color monitor
Click on the first or last page to see other DSC-W30 / DSC-W40 (serv.man4) service manuals if exist.