DSC-V1
6-12
COVER
COVER
1-4.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied.
Note:
For “CAMERA SYSTEM ADJUSTMENTS”, perform in
order of item numbers.
Data setting during camera system adjustments
Perform the following data setting before the camera system ad-
justments.
It is not necessary to perform the following data setting every time
when you perform some items of camera system adjustments con-
tinuously unless the power is turned off. Only when the power is
turned off during this adjustments, perform the data setting again,
then continue the adjustments.
Set up setting:
1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't
set the SET UP setting to “PAL”)
Data setting method
Order Page Address
Data
Procedure
1
00
01
01 
[Set]
2
4F
01
20 
[Write]
3
7F
68
00 
[Write]
4
75
0A
04 
[Write]
5
20
00
29 
[Set]
6
20
01
29 
[Write]
(Note 1)
7
00
01
01 
[Set]
8
4F
0F
01 
[Write]
9
2F
21
0B 
[Write]
10
60
C1
[Read]
Check the data changes
to “02”.
11
4F
02
03 
[Set]
12
60
6C
01 
[Set]
13
Wait for 1 second.
Note 1:
At this time, the set is reset and the power is turned off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click 
[Connect]
 on the SEUS screen to restore
the “connected” state. (In case that the power does not
turn on again, press the power button.)
Note 2:
Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUST-
MENTS”.
After completing the camera system adjustments, release the
data setting:
1) Click 
[Page Edit]
 on the SEUS screen to display the SEUS
PAGE EDIT screen.
2) Click 
[Page]
, and then enter the page “0E”.
3) Click 
[Preset Data Read]
 to display the Set ID input screen.
4) Enter Set ID = “00” and read the initializing data on the SEUS
PAGE EDIT screen.
5) Check that all the data is “FF”.
6) Click 
[Write]
 to write the initializing data to the set.
7) Click 
[Close]
 to close the SEUS PAGE EDIT screen.
8) Release the data setting which has been executed before ad-
justment.
Order Page Address
Data
Procedure
1
4F
01
00 
[Write]
2
7F
68
40 
[Write]
3
75
0A
00 
[Write]
4
60
6C
00 
[Set]
5
4F
02
00 
[Set]
6
2F
21
00 
[Write]
7
4F
0F
00 
[Write]
8
00
01
00 
[Set]
Page of 39